FLIR TG165-X Imaging IR Thermometer (300°C, 80 x 60 Pixels)

- Imaging and optical data:

• IR resolution: 80 × 60 pixels

• Digital image enhancement: No

• Thermal sensitivity/NETD: <70 mK

• Field of view (FOV): 51° × 66°

• Minimum focus distance: 0.3 m (0.98 ft)

• Distance to spot ratio: 24:1

• Pseudo dual range: No

• Image frequency: 8.7 Hz

• Focus: Fixed

- Detector data:

• Focal plane array/spectral range: Uncooled microbolometer/7.5–14 µm

• Detector pitch: 17 μm

- Image presentation:

• Display resolution: 320 × 240 pixels

• Screen: 2.4 in. portrait, 80° viewing angle

• Image adjustment: Automatic

• Image modes:

MSX® (Multi Spectral Dynamic Imaging)

Visual (with temperature reading) 

• Gallery: Yes

- Measurement and analysis:

• Object temperature range: -25°C to 300°C (-13°F to 572°F)

• Accuracy:

50°C to 100°C (122°F to 212°F) - acc. of ±1.5°C (±3°F)

0°C to 50°C/100°C to 300°C (32°F to 122°F/212°F to 572°F) - acc. of ±2.5°C(±5°F)

-25°C to 0°C (-13°F to 32°F) - acc. of ±3°C (±7°F)

• Minimum measurement distance: 0.26 m (0.85 ft.)

• Spotmeter: Center spot on/off

• Color palettes: Iron, Rainbow, Whitehot, Blackhot, Arctic, Lava 

- Storage of images

• Storage media: 4 GB

• Image storage capacity: 50,000 images

• Image file format: JPEG with spot temp in meta tag

- Digital camera:

• Resolution: 2 MP (1600 × 1200 pixels)

• Focus: Fixed

• Field of view: 71° × 56°, adapts to the IR lens

- Worklight and Laser:

• Worklight: LED on/off

• Light output: 100 lumens

• Bullseye laser pointer: Indicating the size of the measurement area

• Laser type: Class 1

- Data communication interfaces:

• Interfaces: USB 2.0

• USB standard: USB Type-C High Speed; data transfer/power

- Power system:

• Battery type Rechargeable Li-ion, 3.7 V battery

• Battery operating time: 5 hours of scanning (LCM medium brightness)

4.5 hours with laser on (LCM medium brightness)

• Battery charge life: 30 days minimum

• Charging system: Battery is charged inside the camera; 4 hrs to 90%,

6 hrs. to 100%

• Power management Adjustable: off, 5 minutes, 15 minutes, 30 minutes

- General:

• Operating temperature range: -10°C to 45°C (14°F to 113°F)

• Encapsulation: IP54 (IEC60529)

• Shock: 25 g (IEC 60068-2-27)

• Vibratio: 2 g (IEC 60068-2-6)

• Drop test: Designed for 2 m (6.56 ft.)

• Safety: CE/CB/EN61010/UL

• Weight: 0.394 kg (13.9 oz)

• Size (L × W × H): 210 × 64 × 81 mm (8.3 × 2.5 × 3.2 in)

• Tripod mounting: UNC ¼”-20

Detail

Datasheet



  • Quality Engagement
  • Easy change and return
  • Delivery Avaliable
  • Favorable payment