GOTT GOTT-PRE-11 Protection Relay Experiment Trainer
Manufacturer: GOTT Model: GOTT-PRE-11 P/N: 191-000 Origin: Malaysia Guarantee: 12 Month - Request a Quotation
- Contact
MODULES:
Signal Relay - Code 191-119
Voltage: 220VDC
NO Contact: 2 sets
Adjustable Single Phase - Code 191-110
Voltage: 0 ~ 240VAC
Current: 1A
Bridge Rectifier - Code 191-111
Voltage: 1000V
Current: 35A
Universal Change Over Switch - Code 191-112
Rated Current 20A
NO Contacts: 4 sets
Simulate Switch Board - Code 191-113
Rated voltage: 240VAC
Push Button X 3 units
Current Relay - Code 191-114
Current: 1.25A to 5A
NO Contact: 1 set
Negative Sequence Relay - Code 191-121
Input Voltage: L1, L2 & L3
Voltage: 220VDC
Time Delay Contactor - Code 159-016
Coil Voltage: 240VAC
Contact: NO & NC
Time : 0…60 seconds
Intermediate Relay - Code 191-117
Voltage: 220VDC
Trigger Current: 1A
NO Contact: 2 sets
NC Contact: 2 sets
Phase Analyzer - Code 191-128
Input: L1, L2 & L3
To check phase voltage in correct / incorrect sequence
Adjustable Three Phase - Code 191-109
Protection Fuse 2A x 3 units
Pilot Lamps L1 , L2 & L3
Fault Current Circuit Breaker 3 Poles
Output: 0…240VAC x 3 units 0…415VAC
Input: AC 415V, 50Hz 3-Phase
Timer Relay - Code 191-116
Voltage: 220VDC
Time: 0.1s to 1.5s
NO Contact: 2 sets
NC Contact: 2 sets
Low Voltage Relay - Code 191-115
Voltage: 40V to 160V
NO Contact: 1 set
NC Contact: 1 set
Impulse Relay - Code 191-123
Voltage: 220VDC
Current: 0.16A
NO Contact: 1 set
NC Contact: 1 set
Synchronous Detector - Code 191-124
Voltage: 220VDC
Voltage: Compare: 110VAC
NO Contact: 1 set
NC Contact: 1 set
Flashing Relay - Code 191-125
Voltage: 220VDC
NO Contact: 2 sets
Overload Relay - Code 191-018
Current: 8A to 16A
NO Contact: 2 sets
Electronic Timer - Code 191-127
Start, stop and reset function
Contactor - Code 191-118
Voltage: 220VDC
NO Contact: 2 sets
NC Contact: 2 sets
Rheostat 100Ω / 1kΩ - Code 191-129
Rheostat 1kΩ / 100W
Rheostat 100Ω / 100W
Indicator and Buzzer - Code 191-130
Lamp Voltage: 240VAC
Buzzer Voltage: 240VAC
Alarm Indicator - Code 191-131
Voltage: 240VAC
AC Voltmeter - Code 191-132
Range: 300V & 500V
AC Ammeter - Code 191-133
Range: 5A & 20A
DC Current & Volmeter - Code 191-134
Voltage Range: 300V
Current Range: 10A
Three Phase Bridge Rectifier - Code 610-308
Three phase rectifier bridge
Maximum Voltage: 400VAC
Maximum current: 10A
Fault Current Circuit Breaker - Code 159-009
Protection Fuse 2A x 3 units
Pilot Lamps L1 , L2 & L3
Fault Current Circuit Breaker 3 Poles
Input: AC 415V, 50Hz 3-Phase
Resistive Load - Code 157-897
Compose of three resistances with possibility to connect in star/delta or parallel, controlled by three switches with 7 steps variable per phase
Max Power : 1200 watt
Voltage : 380/220 Volt (Star/Delta)
U-Link - Code 159-019
For connecting junction point
Safety Connecting Lead - Code 237-001
4mm connecting leads
Vertical Frame Code - 297-000
High level : DIN standard A4 with two shelves
Material: Aluminium
Side Frame: T shape
Size: 3-Layer 1450mm Length
Experiment Manual - Code 191-137
Experiment Projects
Relay Specialty
• Current relay specialty experiment
• Voltage relay specialty experiment
• Electromagnetic time relay experiment
• Intermediate relay specialty experiment
• Signal relay specialty experiment
• Transistors negative sequence voltage relay experiment
• Impact relay specialty experiment
• Flashlight Relay specialty experiment
• Three-phase reclosing device experiment
• Rectifier direction characteristic impedance Relay experiment.
• Differential relay experiment.
• Power direction relay experiment
• Anti-time over current relays characteristics experiment
LINE PROTECTION
• 67-10KV Over-current protection circuit experiment
• Low voltage start over-current protection and overload protection experiment
• Repeat action of manual revert to central signal device experimental
• Repeat action of manual revert to central audio signal device experimental
• Break control loop experiment with lighting surveillance
• Automatic reclosing accelerated protection experiment
• Automatic reclosing after accelerate protection circuit
• Power direction over current protection experiment
• Anti-time over current protection moves specialty experimental
• Distance protection and direction stage-protection setting experiment
• Unilateral power line Rd radiation-current protection experiments
INTEGRATED EXPERIMENTS AND EXPERIMENTAL EVALUATION (EXAMINE DEPEND ON CIRCUITS DESIGNED BY STUDENTS)
• Overcurrent protection and automatic reclosing of three-phase experiment and evaluation
• Low voltage start over-current protection and automatic reclosing (after accelerating) integrative experiment and evaluation
• Current and Voltage instantaneous protection and automatic reclosing (after accelerating) integrative experiment and evaluation
• Overvoltage protection and automatic reclosing (after accelerating) integrative experiment and evaluation
• Three-phase current protection and automatic re-closing (after accelerating) integrative experiment and evaluation
• Over-current protection and automatic reclosing (accelerated) integrative experiment and evaluation
• Low voltage start over-current protection and automatic reclosing (accelerated) integrative experiment and evaluation
• Current at resia Voltage Protection and automatic reclosing (accelerated) integrative experiment and evaluation
• Overvoltage protection and automatic reclosing (accelerated) integrative experiment and evaluation
• Three-phase current protection and automatic reclosing (accelerated) integrated with the experimental evaluation
EXPERIMENTAL BENCH CONFIGURATION NOTE
• Main Control Screen
o GOTT-PRE-17A Three-phase power supply
o GOTT-PRE-01C Breaker and control circuit
o GOTT-PRE-41 resistance disk
o GOTT-PRE-42 resistance disk
o GOTT-PRE-43 resistance disk
o GOTT-PRE-11 AC voltage meter, AC current meter, DC current meter, DC power supply and generatrix
o GOTT-PRE-12 electricalsecond meter, phase meter, optical character brand, signal indication • Experimental Component
o Current relay o Time relay o Intermediate relay
o Signal relay o Automatic reclosing
o Differential relay
o Power direction relay
o Negative sequence voltage relays
o Impact relay o Impedance relay
o Overcurrent relay
o Flash relay o Relay
o Universal change-over switch
o Button and Resistance Disk
o Computer Protection
• Phase Shifter
• High reliability safety experimental cable and accessories
Manuals:
(1) All manuals are written in English
(2) Model Answer
(3) Teaching Manuals
Datasheet
Protection relay experimental device can conduct
experimental operation including power plants, substations and factory relay,
relay, secondary electrical control circuit teaching experiment, which is
applicable in the electrical category, the electrical category related to the
professional coursesteaching experiment.
·
Experiment projects are complete, experiment content is rich, design is
reasonable, which are beneficial to broaden the students’ knowledge.
·
Experimental device has excellent compatibility and scalability. Experimental
installations adopt platform design, laboratory modules using component design
School can based on teaching demand choose experimental module freely. If need
to add depth and breadth of experiments, user simply need to add components.
·
Experimental Device has strong intuitionist. Each relays is the abdomen -
installed on the panel surface, students can clearly see the action of every
relay, and are convenient to set relay values. At the same time, the relays and
other components electrical diagrams of are painting on each panel, which are
complete and consistent teaching materials, can help students understand the
book knowledge, improve the experimental results.
· The
experiments are strong package, the AC-DC power supply, instrumentation, relay
and experimental connecting wire in experiment all fully equipped, school do
not need to add any equipment to complete the experimental content.
·
Experiment has authenticity. The relays used in experiment are relays which are
currently using on-site power system, and better reflect the status of the
power system, and lay a good foundation to engage in design, installation,
debugging, maintenance and other work to for students after graduation for protection
system.
·
Structure is reasonable. The whole structure adopt a three-tier structure,
panel ranking according to the actual line with the flow, experimental function
block is clarity, carefully designing improve experimenter's understanding of the
system, wiring facilitate and the efficiency of the experiment.
· The
experiment device has perfect protection measures. The device provide leakage
circuit breakers and other physical security protection measures, Experimental
lead adopts fully enclosed plastic wire to ensure the students’ operation
safety. Various instruments and power supplies all have a perfect protection
function
- Quality Engagement
- Easy change and return
- Delivery Avaliable
- Favorable payment