For full functionality of this site it is necessary to enable JavaScript.

Teledyne LeCroy WaveAce 212 Oscilloscope (100 MHz, 1 GS/s, 2 Channels)

Bandwidth: 100 MHz
Input Channels: 2
Maximum Input Voltage:± 400 Vpk
Channel-Channel Isolation: ≥ 100:1 at 50 MHz
Sensitivity:2 mV/div - 5 V/div
Time/Division Range:2.5 ns/div - 50 s/div
Acquisition System:
Single-Shot Sample Rate/Ch:2 GS/s on 1 Ch (1 GS/s on 2 Ch)
Equivalent Sample Rate     50 GS/s
Memory: 18 kpts/Ch on 1 Ch (9 kpts/ch on 2 Ch)
Modes: Normal, Auto, Single, Stop
Sources: Ch 1 - Ch 2, EXT, EXT/5, AC Line
Coupling Mode     AC, DC, LF Rej, HF Rej,
Trigger Sensitivity     1 division: DC - 10 MHz
1.5 divisions: 10 MHz - 100 MHz
Display:
Type: Color 5.7" TFT-LCD
Resolution: QVGA; 320 x 234 pixels
Grid Styles: YT (12 horizontal divisions), XY
Internal Storage
Waveform Storage: 20 waveforms and 2 reference waveforms
Setup Storage: 20 setups
Standard Math Functions: add, Subtract, Multiply, Divide, FFT
Measurement Parameters:Amplitude, Average, Base, Burst Width, Cyclical RMS, +Duty Cycle, -Duty Cycle, Fall Time, Frequency, Max, Mean, Min, Overshoot, Peak-Peak, Period, Phase, Rise Time, RMS, Top, +Width, -Width, First Rising-Rising, First Rising-Falling, First Falling-Rising, First Falling-Falling, Last Rising-Rising, Last Rising-Falling, Last Falling-Rising, Last Falling-Falling
Interface
USB (Device): 1
USB (Host): 1
Serial Port: 1
Probes     Qty. (2) ÷10/1 Passive Probes
Scale Factors Manual: ÷1, ÷10, ÷100, ÷1000
Calibration Output:1 kHz square wave, 3Vp-p (typical)
Power:100 - 240 VAC
Dimensions (HWD):154 mm x 305 mm x 133 mm
Weight     2.3 kg (5 lbs)

Details

 

Vertical System

Bandwidth 100 MHz
Rise time 3.5 ns
Input Channels 2
Bandwidth Limiters 20 MHz
Input Impedance 1 MΩ ± 2% || 13 pF ± 3 pF
Input Coupling AC, DC, GND
Maximum Input Voltage ± 400 Vpk
Channel-Channel Isolation ≥ 100:1 at 50 MHz
Vertical Resolution 8 bits
Sensitivity 2 mV/div - 5 V/div
DC Gain Accuracy ±3%: 5 mV/div - 5 V/div (fixed gain ranges)
±4%: 2mV/div and variable gain ranges
Offset Range ±800 mV: 2mV/div - 100 mV/div
±40V: 102 mV/div - 5 V/div
 

Horizontal System

Time/Division Range 2.5 ns/div - 50 s/div
Clock Accuracy 100 ppm
Trigger and Interpolator Jitter .5 ns (pk-pk)
 

Acquisition System

Single-Shot Sample Rate/Ch 2 GS/s on 1 Ch
1 GS/s on 2 Ch
Equivalent Sample Rate 50 GS/s
Memory 18 kpts/Ch on 1 Ch
9 kpts/ch on 2 Ch
 

Acquisition Modes

Averaging Selectable Number of Sweeps:
4, 16, 32, 64, 128, 256
Peak Detect 2.5 ns
Interpolation Linear, Sin x/x
Enhanced Resolution na
Sequence Mode na
 

Triggering System

Modes Normal, Auto, Single, Stop
Sources Ch 1 - Ch 2, EXT, EXT/5, AC Line
Coupling Mode AC, DC, LF Rej, HF Rej,
Pre-trigger Delay memory/(2 * sample rate)
Post-trigger Delay 260 Divisions
Hold-off by Time or Events 100 ns - 1.5 s
Internal Trigger Range ±6 divisions from center
Trigger Sensitivity 1 division: DC - 10 MHz
1.5 divisions: 10 MHz - 100 MHz
External Trigger Sensitivity Ext: 200 mVpp from DC to 10 MHz
300 mVpp from 10 MHz to 100 MHz
Ext/5: 1Vpp from DC to 10 MHz
1.5 mVpp from 10 MHz to 100 MHz
External Trigger Input Range Ext: ±1.2 V, EXT/5: ±6 V
 

Display

Type Color 5.7" TFT-LCD
Resolution QVGA; 320 x 234 pixels
Grid Styles YT (12 horizontal divisions), XY
 

Trigger Types

Optional Advanced Triggers na
Optional Serial Data Triggers na
 

Internal Storage

Waveform Storage 20 waveforms and 2 reference waveforms
Setup Storage 20 setups
 

Math

Number of Math Traces 1
Standard Math Functions Add, Subtract, Multiply, Divide, FFT
Optional Math Functions na
 

Measurements

Number of Measurements Displayed 5
Measurement Parameters Amplitude, Average, Base, Burst Width, Cyclical RMS, +Duty Cycle, -Duty Cycle, Fall Time, Frequency, Max, Mean, Min, Overshoot, Peak-Peak, Period, Phase, Rise Time, RMS, Top, +Width, -Width, First Rising-Rising, First Rising-Falling, First Falling-Rising, First Falling-Falling, Last Rising-Rising, Last Rising-Falling, Last Falling-Rising, Last Falling-Falling
 

Probes

Probes Qty. (2) ÷10/1 Passive Probes
Scale Factors Manual: ÷1, ÷10, ÷100, ÷1000
Calibration Output 1 kHz square wave, 3Vp-p (typical), output to probe hook
 

Interface

GPIB Port (optional) na
USB (Device) 1
Ethernet Port na
USB (Host) 1
Serial Port 1
 

Power Requirements

Voltage 100 - 240 VAC, 45 Hz to 440 Hz
Max. Power Consumption 50 VA
 

Environmental and Safety

Temperature (Operating) 10 °C to 40 °C
Temperature (Non-Operating) -20 °C to 60 °C
Humidity (Operating) 85% RH, 40 °C
Humidity (Non-Operating) 85% RH, 65 °C
Altitude (Operating) 3000 m
Altitude (Non-Operating) 15,266 m
 

Physical Dimensions

Dimensions (HWD) 154 mm x 305 mm x 133 mm
(6" x 12" x 5.25")
Weight 2.3 kg (5 lbs)
 
 
   

 

 

  • Quality Engagement
  • Easy change and return
  • Delivery Avaliable
  • Favorable payment

Apply your mail to get promotion information