Teledyne LeCroy WaveAce 212 Oscilloscope (100 MHz, 1 GS/s, 2 Channels)
Manufacturer: LECROY Model: WaveAce 212 - Request a Quotation
- Contact
Bandwidth: 100 MHz
Input Channels: 2
Maximum Input Voltage:± 400 Vpk
Channel-Channel Isolation: ≥ 100:1 at 50 MHz
Sensitivity:2 mV/div - 5 V/div
Time/Division Range:2.5 ns/div - 50 s/div
Acquisition System:
Single-Shot Sample Rate/Ch:2 GS/s on 1 Ch (1 GS/s on 2 Ch)
Equivalent Sample Rate 50 GS/s
Memory: 18 kpts/Ch on 1 Ch (9 kpts/ch on 2 Ch)
Modes: Normal, Auto, Single, Stop
Sources: Ch 1 - Ch 2, EXT, EXT/5, AC Line
Coupling Mode AC, DC, LF Rej, HF Rej,
Trigger Sensitivity 1 division: DC - 10 MHz
1.5 divisions: 10 MHz - 100 MHz
Display:
Type: Color 5.7" TFT-LCD
Resolution: QVGA; 320 x 234 pixels
Grid Styles: YT (12 horizontal divisions), XY
Internal Storage
Waveform Storage: 20 waveforms and 2 reference waveforms
Setup Storage: 20 setups
Standard Math Functions: add, Subtract, Multiply, Divide, FFT
Measurement Parameters:Amplitude, Average, Base, Burst Width, Cyclical RMS, +Duty Cycle, -Duty Cycle, Fall Time, Frequency, Max, Mean, Min, Overshoot, Peak-Peak, Period, Phase, Rise Time, RMS, Top, +Width, -Width, First Rising-Rising, First Rising-Falling, First Falling-Rising, First Falling-Falling, Last Rising-Rising, Last Rising-Falling, Last Falling-Rising, Last Falling-Falling
Interface
USB (Device): 1
USB (Host): 1
Serial Port: 1
Probes Qty. (2) ÷10/1 Passive Probes
Scale Factors Manual: ÷1, ÷10, ÷100, ÷1000
Calibration Output:1 kHz square wave, 3Vp-p (typical)
Power:100 - 240 VAC
Dimensions (HWD):154 mm x 305 mm x 133 mm
Weight 2.3 kg (5 lbs)
Vertical System |
|
Bandwidth | 100 MHz |
Rise time | 3.5 ns |
Input Channels | 2 |
Bandwidth Limiters | 20 MHz |
Input Impedance | 1 MΩ ± 2% || 13 pF ± 3 pF |
Input Coupling | AC, DC, GND |
Maximum Input Voltage | ± 400 Vpk |
Channel-Channel Isolation | ≥ 100:1 at 50 MHz |
Vertical Resolution | 8 bits |
Sensitivity | 2 mV/div - 5 V/div |
DC Gain Accuracy | ±3%: 5 mV/div - 5 V/div (fixed gain ranges) ±4%: 2mV/div and variable gain ranges |
Offset Range | ±800 mV: 2mV/div - 100 mV/div ±40V: 102 mV/div - 5 V/div |
Horizontal System |
|
Time/Division Range | 2.5 ns/div - 50 s/div |
Clock Accuracy | 100 ppm |
Trigger and Interpolator Jitter | .5 ns (pk-pk) |
Acquisition System |
|
Single-Shot Sample Rate/Ch | 2 GS/s on 1 Ch 1 GS/s on 2 Ch |
Equivalent Sample Rate | 50 GS/s |
Memory | 18 kpts/Ch on 1 Ch 9 kpts/ch on 2 Ch |
Acquisition Modes |
|
Averaging | Selectable Number of Sweeps: 4, 16, 32, 64, 128, 256 |
Peak Detect | 2.5 ns |
Interpolation | Linear, Sin x/x |
Enhanced Resolution | na |
Sequence Mode | na |
Triggering System |
|
Modes | Normal, Auto, Single, Stop |
Sources | Ch 1 - Ch 2, EXT, EXT/5, AC Line |
Coupling Mode | AC, DC, LF Rej, HF Rej, |
Pre-trigger Delay | memory/(2 * sample rate) |
Post-trigger Delay | 260 Divisions |
Hold-off by Time or Events | 100 ns - 1.5 s |
Internal Trigger Range | ±6 divisions from center |
Trigger Sensitivity | 1 division: DC - 10 MHz 1.5 divisions: 10 MHz - 100 MHz |
External Trigger Sensitivity | Ext: 200 mVpp from DC to 10 MHz 300 mVpp from 10 MHz to 100 MHz Ext/5: 1Vpp from DC to 10 MHz 1.5 mVpp from 10 MHz to 100 MHz |
External Trigger Input Range | Ext: ±1.2 V, EXT/5: ±6 V |
Display |
|
Type | Color 5.7" TFT-LCD |
Resolution | QVGA; 320 x 234 pixels |
Grid Styles | YT (12 horizontal divisions), XY |
Trigger Types |
|
Optional Advanced Triggers | na |
Optional Serial Data Triggers | na |
Internal Storage |
|
Waveform Storage | 20 waveforms and 2 reference waveforms |
Setup Storage | 20 setups |
Math |
|
Number of Math Traces | 1 |
Standard Math Functions | Add, Subtract, Multiply, Divide, FFT |
Optional Math Functions | na |
Measurements |
|
Number of Measurements Displayed | 5 |
Measurement Parameters | Amplitude, Average, Base, Burst Width, Cyclical RMS, +Duty Cycle, -Duty Cycle, Fall Time, Frequency, Max, Mean, Min, Overshoot, Peak-Peak, Period, Phase, Rise Time, RMS, Top, +Width, -Width, First Rising-Rising, First Rising-Falling, First Falling-Rising, First Falling-Falling, Last Rising-Rising, Last Rising-Falling, Last Falling-Rising, Last Falling-Falling |
Probes |
|
Probes | Qty. (2) ÷10/1 Passive Probes |
Scale Factors | Manual: ÷1, ÷10, ÷100, ÷1000 |
Calibration Output | 1 kHz square wave, 3Vp-p (typical), output to probe hook |
Interface |
|
GPIB Port (optional) | na |
USB (Device) | 1 |
Ethernet Port | na |
USB (Host) | 1 |
Serial Port | 1 |
Power Requirements |
|
Voltage | 100 - 240 VAC, 45 Hz to 440 Hz |
Max. Power Consumption | 50 VA |
Environmental and Safety |
|
Temperature (Operating) | 10 °C to 40 °C |
Temperature (Non-Operating) | -20 °C to 60 °C |
Humidity (Operating) | 85% RH, 40 °C |
Humidity (Non-Operating) | 85% RH, 65 °C |
Altitude (Operating) | 3000 m |
Altitude (Non-Operating) | 15,266 m |
Physical Dimensions |
|
Dimensions (HWD) | 154 mm x 305 mm x 133 mm (6" x 12" x 5.25") |
Weight | 2.3 kg (5 lbs) |
- Datasheet
- Specification
- Videos & Demos
- Software & Utilities
- Firmware
- Manuals
- Application Notes
- Request Demo
- Quality Engagement
- Easy change and return
- Delivery Avaliable
- Favorable payment