For full functionality of this site it is necessary to enable JavaScript.

Advanced Energy OLS10K Rack-Mount Power Supply (up to 100kV)

- Output Power: 10 kW max at full rated output voltage and current
- Output Voltage: The OLS10K offers output voltages up to 100 kV.
- Output Current: Up to 10 A for 1 kV and 100 mA for 100 kV
- Input Voltage: 208 VAC ±10% (187 ~ 229 VAC) 47 ~ 63 Hz 3 phase plus protective earth
- Input Current: < 36 A per phase
- Voltage Ripple: Voltage Mode: < 0.05% of rated voltage +2 V, peak to peak or < 0.01% of rated voltage +1 Vrms
- Voltage Ripple: Current Mode: < 0.5% of rated voltage peak to peak
or < 0.1% of rated voltage rms
- Line Voltage Regulation: < 0.01% +0.5 V change in output voltage for a 10% change in line voltage
- Load Voltage Regulation: < 0.01% +0.5 V change in output voltage for 0 ~ 100% change in load current
- Line Current Regulation: < 0.5% of rated current
- Load Current Regulation: < 0.5% of rated current for 0 ~ 100% change in output
- Polarity: Positive or negative to order
- Specification Range: Specifications apply above 5% of rated output voltage. The output can be controlled down to < 0.25% of rated output voltage.
- Calibration: Calibration between voltage demand, output voltage, and voltage monitor ±0.2% of setting or ±0.05% of rating, whichever is greater
- Recovery Time: < 200 ms to within 0.1% of previous operating level following a short circuit or arc. Max overshoot 2% of rated output voltage.
- Temperature Coefficient: < 100 ppm/°C
- Drift: < 0.01% per hour after 1 h warmup, typically < 0.02% per 8 h after 1 h warmup, at constant load, line, and temperature
- Operating Temperature: 0 ~ 40°C (32 ~ 140°F)
- Storage Temperature: -20 ~ 70°C (-4 ~ 158°F)
- Humidity: 80% max relative humidity up to 31°C (88°F), reducing linearly to 50% at 40°C (104°F). Non-condensing
- Altitude: Sea level to 2000 m (6500')
- Installation Category: II (BS EN61010-1)
- Pollution Degree: 2 (BS EN61010-1)
- Usage Indoor use only
- Interface:
Analog remote control interface as standard, control is via a 25-way female D-type connector
Optional digital RS232 remote control, 9-way female D-type connector available
- Dimension (W x D x H):
Up to 80 kV: 43 x 51.6 x 26.6 cm3 (17 x 20.3 x 10.5 in3)
Over 80 kV: 43 x 61.4 x 26.6 cm3 (17 x 24.2 x 10.5 in3)
- Weight: 45 kg (99 lb)
- Accessories: OLS10K 3M HV Cables, OLS10K 5M HV Cables, OLS10K 10M HV Cables

Details

Datasheet

  • Quality Engagement
  • Easy change and return
  • Delivery Avaliable
  • Favorable payment

Apply your mail to get promotion information