Standard Indications
Type: ARV
Full Scale: 2.5 bar
Display: 2.5 bar
Resolution: 0.0005 bar
Main Features:
Accuracy (Linearity And Hysteresis) : ≤ ± 0.05 % F.S.
Pressure Units : bar – mbar – psi – Mpa – kPa – kg/cm2 – mHg - mmHg – mmH2O – mH2O
Temperature Indication: Unit °C - °F
a) Resolution: 0.1 °C
b) Accuracy: ± 1 °C
Reference Temperature: 0 … +50 °C
Operating Temperature: -10 … +60 °C
Relative Umidity: < 90 % not condensed
Temperature Effect (1 °C):
a) on zero: ≤ ± 0.002%
b) on sensitivity: ≤ ± 0.002%
Internal Resolution: 24 bit
Conversions Per Seconds: 10 (100ms)
Display Lcd Backlight: CUSTOM 7 SEGMENT
Display Height: 13mm
Resolution: 1, 2, 5, 10
Function Digital Filter: from 0 to 5
Function Zero: 100 % F.S.
Function Peak: Positive / Negative (VACUUM)
Function Loop: Switch between pressure and temperature
Function Lock (LOC): Protection of programming
Communication Port: USB 2.0
Transmission Type: on DEMAND or CONTINUOUS
Transmission In Countinuous Mode: 10 values per second
Max Distance: 5 m
Power Supply: 1 Li-Ion Battery 3.6V 1800mA/h
Autonomy: 50 hours continuous
Battery Recharge: From USB port (5Vdc)
Mechanical Limit Values::
a) service pressure: 100% F.S.
b) limit pressure: 150% F.S.
c) breaking pressure: >300% F.S.
d) highly dynamic pressure: 75% F.S.
Process Coupling: 1/2" G Male
Seal Recommended: USIT A 63-18
Tightening Wrench: 27 mm
Tightening Torque: 28 Nm
Protection Class (EN 60529): IP40
Material Sensor: 17-4 PH STAINLESS STEEL
Container Material: ALUMINUM
Internal Datalogger: Pressure and Temperature
Internal Clock / Calendar: YES
Max Number Of Storing Points: 130000 (only pressure); 65000 (pressure and temperature)
Storing Rate: settable (from 1s to 24 hours)
Max Data Logger Duration (2): 365 days
Wireless Transmission: 868 MHz
Max Distance: 40 m in free space
Max Number Of Manometers In Network: 32
Serial Port (3): RS232C
Baud Rate: Fixed at 9600 baud
Type Of Transmission: On DEMAND or continuous
Built-In Version: Case for panel mounting
Material: Glass-fiber reinforced technopolymer
External Power Supply: without battery, power supply and usb cable from 12 to 24Vdc