Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Working range:
Voltage 0–1200V, Current 0–800A, Power 20kW
Minimum working voltage: 20V@800A
Constant current loading:
Range 80/400/800A, Resolution 1/5/10mA, Accuracy 0.04%+0.06%F.S
Constant voltage loading:
Range 150/600/1200V, Resolution 1/5/10mV, Accuracy 0.025%+0.025%F.S
Constant resistance load:
Range: 2.5mΩ-0.25kΩ(150V), 0.1Ω-1kΩ(600V), 2.5Ω-5kΩ(1200V). Resolution 10mA/Vsense. Accuracy Vin/Res(±0.2%+0.2%F.S).
Constant power loading:
Range 2000/10000/20000W, Resolution 100/500/1000mW, Accuracy 0.2%+0.2%F.S.
Current change rate:
Setting range 1mA/μs-2.2A/μs(80A), 5mA/μs-11A/μs(400A), 10mA/μs-22A/μs(800A). Resolution 1/5/10mA/μs.
Specification:
Dimensions 426mm×665mm×650mm(W×H×D), Weight 113kg.