Functional Configuration: MAX300V, ACIR
AC Internal Resistance
Measurement method: AC four-terminal method
Current frequency: 1kHz±0.2Hz
Resistance range: 3mΩ / 30mΩ / 300mΩ / 3Ω / 30Ω / 300Ω / 3kΩ / 30kΩ
Maximum display value: 3.10000mΩ / 31.0000mΩ / 310.00mΩ / 3.1000Ω / 31.000Ω / 310.00Ω / 3.1000kΩ / 31.000kΩ
Resistance resolution: 0.1μΩ / 1μΩ / 10μΩ / 100μΩ / 1mΩ / 10mΩ / 100mΩ / 1Ω
Measuring current: 100mA
Resistance accuracy: 3mΩ range: ±(0.5% × Reading value + 10 digits); 3mΩ or more range: ±(0.5% × Reading value + 5 digits)
DC Voltage
U-RANGE: 100V / 300V
Voltage resolution: 1mV / 1mV
Maximum display value: ±100.000V / ±310.000V
Voltage accuracy: ±(0.01% × Reading value + 3 digits)
Panel function: Touch screen operation, storage of 100 sets of test conditions, with the open circuit detection, comparator, speed selection, range selection, function selection, etc.
Interface function: RS232, LAN, I/O
Operational environment: Operational environment: 0°C–40°C, below 80%RH (no condensation); Accuracy guarantee environment: 23°C±5°C, below 80%RH (no condensation)
Power supply specifications: AC220V±10%, 50Hz/60Hz, 20VA
Dimensions (W×H×D mm): 213×88×300