Input
Input range (operating): 90 - 264 Vac
Input range (nominal): 115 / 230 Vac. Input through IEC connector
Frequency: 47 - 63 Hz
Input current: 8.8 A RMS max input current At 100 Vac
Output
Output rating: 12 V @ 62.3 A; 748 W / 5.0 Vsb @ 2.4 A; 12 W: 90 - 264 Vac
Rated load: 760 W maximum. No derating over operating temp range
Minimum load: 12 V @ 0.0 A / 5.0 Vsb @ 0.0 A. No loss of regulation
Operating temperature: -10 ° to 50 °C
Storage temperature: -40 ° to 85 °C
Operating relative humidity: 5% to 95% non-condensing
Functions: Short circuit protection; Overload protection (OCP); Overvoltage protection (OVP); Overtemperature protection
O/P Voltage Set Point: 12.0 Vdc
Set Point Tolerance: ± 0.2%
Total Regulation: ± 1%
Minimum Current: 0 A
Maximum Current: 62.3 A
Output Ripple P/P: 120 mV
Stand-by Voltage: 3.3 V @ 2.4 A
Air Flow: Standard