Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Input
Input voltage range: -48 Vdc Nominal -38 to -60 Vdc
Input surge current: 60 Vdc (cold start) 40 A max.
Input current: -48 Vdc @ 250 W 7 A
Output
Maximum power: 200 LFM forced air 250 watts
Total regulation (line and load)
Main output: ± 2.0%
Auxiliary outputs: ± 5.0%
Turn-on delay: -48 Vdc input 2.0 s max
Environmental Specifications
Thermal performance:
Operating ambient: -50 °C to +70 °C
Non-operating: -40 °C to +85 °C
0 °C to 50 °C ambient, 200 LFM forced air, 250 LFM with cover: 250 W
0 °C to 50 °C ambient, 0 °C to 40 °C with cover, Convection cooled: 175 W
50 °C to 70 °C ambient, Convection cooled: Derate linearly to 50% load
Relative humidity: Non-condensing Per GR-63-Core
Functions: Integrated control and monitoring features; Overcurrent, overvoltage and overtemperature protectio
Weight: 650g (22 oz)
Ordering Information
Output Voltage: 12V
Output Current
Min: 0A
Max (free air): 14.6A
Max (forced air) : 21A
Ripple: 120mV
Total Regulation: ± 2.0%