Input
Input voltage range: Universal input: 85 - 264 Vac
Input frequency range: 47 - 63 Hz
Input surge current: 264 Vac (cold start) 40 A max.
Input current:
120 Vac @ 250 W, 2.78 A rms
230 Vac @ 250 W, 1.36 A rms
Output
Maximum power: 200 LFM forced air; 250 LFM with cover: 250 watts
Adjustment range: Main output: ±5%
Total regulation (line and load)
Main output: ± 2.0%
Auxiliary outputs: ± 5.0%
Turn-on delay: @ 120 Vac Input 2.0 s max
Environmental Specifications
Thermal performance:
Operating ambient: 0 °C to +70 °C
Non-operating: -40 °C to +85 °C
0 °C to 50 °C ambient, 200 LFM forced air, 250 LFM with cover: 250 W
0 °C to 50 °C ambient, 0 °C to 40 °C with cover, Convection cooled: 175 W
50 °C to 70 °C ambient, Convection cooled: Derate linearly to 50% load
Relative humidity: Non-condensing: 5 - 95% RH
Functions: Integrated control and monitoring features; Overcurrent, overvoltage and overtemperature protectio
Ordering Information
Output Voltage: 24V
Output Current
Min: 0A
Max (free air): 7.3A
Max (forced air) : 10.5A
Ripple: 240mV
Total Regulation: ± 2.0%