Rated value:
- Input voltage: 0~360V
- Input current: 0.1mA~30A
- Input power: 150W
Range/ Accuracy/ Resolution
Load accuracy: 0-36V/ ±(0.05%+0.03%FS)/ 1mV
0-360V/ ±(0.05%+0.03%FS)/ 10mV
0-3A/ ±(0.05%+0.05%FS)/ 0.1mA
0-30A/ ±(0.05%+0.05%FS)/ 1mA
Rated voltage mode: 1.5V-36V/ ±(0.05%+0.03%FS)/ 1mV
1.5V-360V/ ±(0.05%+0.03%FS)/ 10mV
Rated current mode: 0-3A/ ±(0.05%+0.05%FS)/ 0.1mA
0-30A/ ±(0.05%+0.05%FS)/ 1mA
Rated resistance mode: 0.05Ω-5Ω/ ±(0.2%+0.2%FS)/ 0.001Ω
0.5Ω-50Ω/ ±(0.1%+0.1%FS)/ 0.01Ω
5Ω-500Ω/ ±(0.1%+0.1%FS)/ 0.1Ω
500KΩ-5KΩ/ ±(1%+1%FS)/ 1Ω
Rated power mode: 0-50W/ ±(0.1%+0.1%FS)/ 1mW
0-150W/ ±(0.1%+0.1%FS)/ 10mW
0-300W/ ±(0.1%+0.1%FS)/ 0.1W
Voltage measurement accuracy: 0-9.9999V/ ±(0.05%+0.03%FS)/ 0.1mV
10.000-99.999V/ ±(0.05%+0.03%FS)/ 1mV
100.00-360.00V/ ±(0.05%+0.03%FS)/ 10mV
Current measurement accuracy: 0-9.9999A/ ±(0.05%+0.05%FS)/ 0.1mA
10.000-30.000/ ±(0.05%+0.05%FS)/ 1mA
Battery test function:
- Input= 0.8-360V Max measurement, capacity= 999A/H
- Resolution=0.1mA; Timer range=1~60000sec
Dynamic test mode: A or B test time: 0.05mS-999S; Error<2.5% + 0.05mS
U disk storage: YES
Impedance in the input terminal: ≥200KΩ
Dimensions: W*H*D 215mm*88mm*350mm
Weight: 5.5Kg