The STRCV has a sensor in the end of the bent probe that picks up the
current signal originating from either the ST500, ST800, DCI-50, or
DCI-100 and indicates the direction of that current pulse on the display
via a left or right directional LED.
For identifying concentric neutral primary cables many times the
STRCV needs to be more sensitive for applications including but not
limited to:
1) Cables in Conduit
2) Network Applications
3) Long runs of cable (>1 mile)
The STRCV-CT incorporates a BNC connector so that a "wrap around
CT" can be used rather than the sensor at the end of the bent probe.
STRCV Switch Positions
● OFF position - Unit Off for storage and transit.
● High - 300+ Amp position
● Medium- 50 – 300 Amps position
● Low- Less than 50 Amp position
“T" position tests internal battery voltage and display function.