- Voltage / frequency : measurement automatic upon connection to installation: from 2 to 550 V (DC or RMS) / from 15.3 to 450 Hz
- Differential test:
+ I∆n = 10 – 30 – 100 – 300 - 500 mA - Adjustable : 6mA to 650 mA
+ non-tripping test: at ½ I∆n
+ tripping time measurement: at I∆n, 2 I∆n, 5 I∆n, 150 mA, 250 mA
+ tripping current / time measurements:ramp from 0.5...1.06 I∆n, in 3% increments
+ fault voltage: 5.0 to 50.0 V by calculation I∆n x RE- short-circuit current: displayed up to 40 kA by calculation IK = UREF / ZL-PE
- Earth loop / live earth:
+ by RCD test without tripping and without tripping using 1 auxiliary rod: from 0.1 to 4000Ω
+ calculation of fault voltage and short-circuit current
- Current measurement: using clamp connections 20 A (MN20 & C172) or 200 A (C174)
- Phase rotation order: on installation frequencies from 15.3 to 64 Hz and voltage 90 to 550 V using conventional method (3 wires) or sequential method (2 wires)
- General specifications
+ Power supply: 6 x 1.5 V batteries or rechargeable batteries complies with standards EN 61010-1 and EN 61557, Electromagnetic compatibility (EMC) rating EN 61326
+ IP 54
+ Dimensions: 211 x 108 x 60 mm / 900 g
Thiết bị tiêu chuẩn: Supplied with "hands free" carrying strap and accessories bag:
1 mains lead
1 3-wire lead
3 test probes / 3 crocodile clips
1 user's manual in 5 languages
1 data transfer application software
1 communication lead
Innovative and particularly user-friendly, the C.A 6030 RCD is particularly easy to use and offers high metrological performance for the testing protection systems and installations' compliance with the European and international standards NF C 15-100, VDE 0100, NIN/NIV, IEEE 16th, ÖVE EN-1.