For full functionality of this site it is necessary to enable JavaScript.

Comet M1320 Multilogger - universal 4 channel thermometer hygrometer (AC adapter 230Vac/5Vdc)

Measured value: Temperature, Relative humidity, Counted values (dew point…), Current, Voltage, Two-state signal, Pulses

Temperature sensor - external probe PT1000:

  Measuring range: -200 to +600 °C

  Accuracy: ±0.2 °C (-200 to +100 °C);

                   ±0.2 % from reading from +100 to +600 °C

  Resolution: 0.1 °C

Temperature + humidity sensor - external probe T+RH DIGI:

  Measuring range: according to the connected probe Digi/M

  Accuracy: according to the connected probe Digi/M

  Resolution 0.1 °C

Dew point:

  Measuring range: according to the connected probe Digi/M

  Accuracy: according to the connected probe Digi/M

  Resolution: 0.1 °C

DC voltage:

  Measuring range: 0 to 10 V

  Accuracy: ±10 mV

  Resolution better than: 100 µV

DC current:

  Measuring range: 0 to 20 mA

  Accuracy: ±20 µA

  Resolution better than: 0.1 µA

Binary signal:

  Input voltage for level “switched": <0.4 V/> 2 V

  Minimum/maximum input voltage: 0 V/+30 V DC

  Impedance of the “switched on”: < 10 kOhm/> 300 kOhm

Counter input:

  Range of counter: 24 bit (16 777 215) the counter overflow can be allowed

  Maximum input frequency: 200 Hz

Operating temperature: -10 to +60 °C

Channels: 2x external temperature probe or connectable temperature+humidity probe,

2x binary, counter, voltage and current input

Counted values: dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy

Memory: 1 000 000 values (noncyclic record), 600 000 values (cyclic record)

Recording interval: 1s to 24 hours

Display and alarm refresh: each 10 s

Recording mode: noncyclic - data logging stops after filling the memory

                            cyclic - after filling memory oldest data is overwritten by new

Available temperature units: degrees Celsius, degrees Fahrenheit

Communication interface: Ethernet, USB, RS232

Ethernet communication protocols: WWW, SNMPv1, XML, DATALINK

Alarm protocols: E-Mail

Power: AC adapter 230Vac/5Vdc (neccessary for Ethernet interface)

Protection class: IP20

Dimensions (without connectors): 178 x 95 x 37mm, without attached cables

Weight (including batteries): approx. 380 g

Included in delivery:

  M1320

  Instruction Manual

  Traceable Calibration Certificate

  3x Rechargeable Battery AA

  Power Supply

  USB Cable

  Wall Holder

  FREE FULL VERSION Analytical Software COMET Vision

  EXTERNAL PROBES ARE NOT INCLUDED IN DELIVERY

Details

Datasheet


Manual

  • Quality Engagement
  • Easy change and return
  • Delivery Avaliable
  • Favorable payment

Apply your mail to get promotion information