Accuracy: ± 1 %
Compliance: CE
Display Note: 90° tiltable, 3-1/2 digit
Display Type: LCD
Accuracy Note: ± 1% FS including linearity over 59 to 77°F (5 to 25°C) and 5 to 60 psia (0.34 to 4 bar); Series GFC X143, X144, X145, ± 1.5% FS
Output Detail: Linear 0 to 5 VDC and 4 to 20 mA
Output Signal: Current, Voltage
Pressure Type: Gauge
Repeatability: ± 0.25%
Response Time: 2 s
Supply Voltage: ± 12 Vdc
Pressure Limits: Up to 500 psi
Materials, Wetted: 316 Stainless Steel, Aluminum, Brass, Fluoroelastomer
Supply Power Type: DC
Response Time Note: 2 s to within ± 2% of actual flow
Media Compatibility: Air, Argon, Carbon dioxide, Helium, Hydrogen, Nitrogen, Non-Corrosive Dry Gases, Oxygen
Particulate Size, Max: 5 microns
Leak Rate Under Vacuum: less than 10^⁻9 cc He/s
Process Connection Size: 3/4 in
Process Connection Type: Compression Fitting
Volumetric Flow Rate, Max: 1000 l/min
Volumetric Flow Rate, Min: 0 ml/min
Operating Temperature, Max: 122 °F
Operating Temperature, Min: 32 °F
Material Construction Option: Aluminum