ESCO CCL-170B-8-P CelCulture® CO2 Incubator (170 L, 230 VAC, 50/60 Hz)
Manufacturer: ESCO Model: CCL-170B-8-P P/N: 2170101 - Contact
IR SENSOR MODEL WITH INTEGRATED COOLING SYSTEM
CelCulture® Incubator 170 L: IR Sensor, CO2 Control, Moist Heat Decon, Peltier System, 230 VAC, 50/60 Hz
TEMPERATURE:
Temperature Control Method: Direct heat & Air Jacket using Microcontroller PI
Ambient Temperature Range: 18 to 32°C (64.4 to 89.6°F)
Temperature Range, °C: 8°C below ambient to 60°C
Temperature Uniformity*, °C:
Heating mode: < ±0.7
Cooling mode: < ±2.0
Temperature Accuracy*, °C: < ±0.1
Temperature Recovery Time** (after 30 seconds door opening, 98% from initial value): ≤5 minutes
CO2:
CO2 Control System: Microcontroller PI
Range, % CO2: 0-19.5
Accuracy***, % CO2: ±0.1
Sensor: Infrared (IR) Sensor
Recovery Time**** (after 30 seconds door opening, 98% from initial value):
Standard Unit: ≤5 minutes
Suppressed O2 model: ≤6 minutes
HUMIDITY:
Humidity Method: Humidity Pan
Humidity Range, %RH (at 37°C)*******: 85-90
PHYSICAL CONSTRUCTION:
Interior Volume: 170 L
External Dimensions (W x D x H): 660 x 789 x 900 mm
Internal Dimensions (W x D x H): 505 x 535 x 633 mm
Chamber Construction: Main Body Electrogalvanized steel with Isocide™ antimicrobial coating
Interior Material: Stainless steel, type 304
Number of Shelves: 4
Maximum Number of Shelves: 7
ELECTRICAL CONFIGURATION:
110-130 VAC, 50/60 Hz: Full Load Amps: 9.2 A
220-240 VAC, 50/60 Hz: Full Load Amps: 4.2 A
Net Weight: 113 kg
CONTAMINATION CONTROL:
Contamination Control Methods:
1) Main body is electro-galvanized steel with Isocide™ antimicrobial coating;
2) 90˚C moist heat OVERNIGHT decontamination cycle (HPA validated);
3) ULPA filter********
4) 0.2-micron inlet filter for gas inputs;
5) 1-micron air circulation filter
All data recorded is specified for standard models with unloaded chambers and tested under optimum factory setting conditions of 23°C and 60% ambient humidity.
*Results are achieved when tested at 37°C as set point. Results may vary if set point changes and calibration is needed.
**For temperature not exceeding 37.2°C.
***Results are achieved when tested at 5% CO2 as set point. Results may vary if set point changes and calibration is needed.
****For CO2 level not exceeding 5.2%.
*****Results are achieved when tested at 5% O2 as set point. Results may vary if set point changes and calibration is needed.
****** For O2 level not lower than 4.8%.
******* Esco does not guarantee condensation-free chamber at humidity level higher than 90%.