ESCO CCL-170B-8-P CelCulture® CO2 Incubator (170 L, 230 VAC, 50/60 Hz)

IR SENSOR MODEL WITH INTEGRATED COOLING SYSTEM

CelCulture® Incubator 170 L: IR Sensor, CO2 Control, Moist Heat Decon, Peltier System, 230 VAC, 50/60 Hz


TEMPERATURE:

Temperature Control Method: Direct heat & Air Jacket using Microcontroller PI

Ambient Temperature Range: 18 to 32°C (64.4 to 89.6°F)

Temperature Range, °C: 8°C below ambient to 60°C

Temperature Uniformity*, °C:

Heating mode: < ±0.7

Cooling mode: < ±2.0

Temperature Accuracy*, °C: < ±0.1

Temperature Recovery Time** (after 30 seconds door opening, 98% from initial value): ≤5 minutes


CO2:

CO2 Control System: Microcontroller PI

Range, % CO2: 0-19.5

Accuracy***, % CO2: ±0.1

Sensor: Infrared (IR) Sensor

Recovery Time**** (after 30 seconds door opening, 98% from initial value):

Standard Unit: ≤5 minutes

Suppressed O2 model: ≤6 minutes


HUMIDITY:

Humidity Method: Humidity Pan

Humidity Range, %RH (at 37°C)*******: 85-90


PHYSICAL CONSTRUCTION:

Interior Volume: 170 L

External Dimensions (W x D x H): 660 x 789 x 900 mm

Internal Dimensions (W x D x H): 505 x 535 x 633 mm

Chamber Construction: Main Body Electrogalvanized steel with Isocide™ antimicrobial coating

Interior Material: Stainless steel, type 304

Number of Shelves: 4 

Maximum Number of Shelves: 7


ELECTRICAL CONFIGURATION: 

110-130 VAC, 50/60 Hz: Full Load Amps: 9.2 A

220-240 VAC, 50/60 Hz: Full Load Amps: 4.2 A


Net Weight: 113 kg


CONTAMINATION CONTROL: 

Contamination Control Methods:

1) Main body is electro-galvanized steel with Isocide™ antimicrobial coating;

2) 90˚C moist heat OVERNIGHT decontamination cycle (HPA validated);

3) ULPA filter********

4) 0.2-micron inlet filter for gas inputs;

5) 1-micron air circulation filter


All data recorded is specified for standard models with unloaded chambers and tested under optimum factory setting conditions of 23°C and 60% ambient humidity.

*Results are achieved when tested at 37°C as set point. Results may vary if set point changes and calibration is needed.

**For temperature not exceeding 37.2°C.

***Results are achieved when tested at 5% CO2 as set point. Results may vary if set point changes and calibration is needed.

****For CO2 level not exceeding 5.2%.

*****Results are achieved when tested at 5% O2 as set point. Results may vary if set point changes and calibration is needed.

****** For O2 level not lower than 4.8%.

******* Esco does not guarantee condensation-free chamber at humidity level higher than 90%.