For full functionality of this site it is necessary to enable JavaScript.

HORIBA EC2000-S Benchtop Conductivity Meter (~2.000S/cm; 0.001~20MΩ・cm; ~100ppt)

Configuration of a machine includes

Meter EC2000: 1

9382-10D Ti/Pt black plastic-body conductivity electrode k=1.0 with built-in temperature sensor: 1

503-S Conductivity standard solutions kit: 1


Conductivity Range0.000 to 1.999 µS/cm (k = 0.1)

                                    2.00 to 19.99 µS/cm (k = 0.1, 1)

                                    20.0 to 199.9 µS/cm (k = 0.1, 1, 10)

                                    200 to 1999 µS/cm (k = 0.1, 1, 10)

                                    2.00 to 19.99 mS/cm (k = 0.1, 1, 10)

                                    20.0 to 199.9 mS/cm (k = 1, 10)

                                    0.200 to 2.000 S/cm (k = 10)

- Units: Auto ranging S/cm, S/m (µS ↔ mS ↔ S)

- Resolution: 0.05% full scale

- Accuracy: ± 0.6% full scale; ± 1.5% full scale > 18.0 mS/cm

- Reference temperature: 15.0 to 30.0 °C (adjustable)

- Temperature coefficient; 0.00 to 10.00 % per °C (adjustable)

- Cell constants: 0.070 to 13.00 (adjustable)

- Calibration points: Up to 4 (Auto) / Up to 5 (Manual)

Resistivity range: 0.001 MΩ・cm to 20.0 MΩ・cm

- Resolution: 0.5% full scale

- Accuracy: ± 0.6% full scale; ± 1.5% full scale > 1.80 MΩ・cm

Total Dissolved Solids (TDS) Range: 0.01 to 9.99 mg/L (ppm)

                                                               10.0 to 99.9 mg/L (ppm)

                                                               100 to 999 mg/L (ppm)

                                                               1.00 to 9.99 g/L (ppt)

                                                               10.0 to 100 g/L (ppt)

- Resolution: 0.01, 0.1, 1 mg/L ↔ g/L (ppm ↔ ppt)

- Accuracy: ± 0.1% full scale

- TDS Curves: EN27888, 442, NaCl, Linear (0.40 to 1.00)

Salinity range: 0.0 to 100.0 ppt / 0.00 to 10.00 %

- Resolution: 0.1 ppt / 0.01%

- Accuracy: ± 0.2% full scale

- Salinity curves: NaCl / Seawater

- Calibration option: Yes (Manual; 1 point)

Temperature range: -30.0 to 130.0°C / -22.0 to 266.0°F

- Resolution: 0.1 °C / °F

- Accuracy: ± 0.5 °C / ± 0.9 °F

- Calibration option: Yes (± 10.0 °C / ± 18.0 °F range in 0.1 °C increments)

Memory: 2000

Auto Data Log: Yes

Real-time Clock: Yes

Date & Time Stamp: Yes

Measurement modes: Auto Stable / Auto Hold / Real Time

Auto shut-Off: Yes (Programmable: up to 30 mins.)

Electrode status: On screen display

Diagnostics: Yes

Password setting: Yes

Software upgrade: Yes

PC / Printer communication: Phono jack (USB / RS232C)

Meter Inputs: BNC, phono, DC sockets

Display: 5" Custom LCD with backlight and 320 segments

Power requirement: AC adaptor 100 - 240V, 50 - 60Hz

Dimensions & Weight: 155(L) x 150(W) x 67(H) mm, 765g

Details

Manual


Brochure

  • Quality Engagement
  • Easy change and return
  • Delivery Avaliable
  • Favorable payment

Apply your mail to get promotion information