Order code: 902820/51-415-1001-1-24-265-26-26/362
Image may be a representation. See datasheet for product details.
Operating temperature (additional versions upon request, for restrictions see DIN 43772): -50 to +600 °C (thin film temperature sensor)
Measuring insert (additional versions upon request): 1× Pt100 in three-wire circuit (not in conjunction with transmitter 331 or 336)
Tolerance class according to DIN EN 60751:2009 / IEC 60751:2008: Class B (standard) (-50 to +500 °C)
Thermowell diameter D in mm (additional versions upon request): Ø 24 mm reduced to Ø 12.5 mm
Thermowell dimensions (insertion length/total length): 65 mm/200 mm (previously form D4 according to DIN 43767)
Thermowell material: Stainless steel 1.4571 (operating temperature 600 °C)
Protection tube material: Stainless steel 1.4571
Extra code: Ex-protection Ex according to Directive 2014/34/EU (ATEX)
RTD temperature probes for process technology are predominantly used for temperature measurement in liquids and gases.
Datasheet