Teledyne LeCroy WaveJet 322A Oscilloscope (200 MHz, 1 GS/s, 2 channels)
Manufacturer: LECROY Model: WaveJet 322A - Contact
Vertical System | |
Bandwidth | 200 MHz |
Rise time | 1.75 ns |
Input Channels | 2 |
Bandwidth Limiters | 20 MHz |
Input Impedance | 1 MΩ ± 1.5% || 20 pF |
Input Coupling | AC, DC, GND |
Maximum Input Voltage | ± 400 Vpk |
Channel-Channel Isolation | ≥ 34 dB from DC - 100 MHz ≥ 30 dB at 200 MHz |
Vertical Resolution | 8 bits |
Sensitivity | 2 mV/div - 10 V/div |
DC Gain Accuracy | ±(1.5% + 0.5% of Full Scale) |
Offset Range | ±1 V: 2 mV/div - 50 mV/div ±10 V: 50.2 mV/div - 500 mV/div ±100 V: 502 mV/div - 10 V/div |
Horizontal System | |
Time/Division Range | 2 ns/div - 50 s/div |
Clock Accuracy | 10 ppm |
Trigger and Interpolator Jitter | 500 ps (pk-pk) |
Acquisition System | |
Single-Shot Sample Rate/Ch | 1 GS/s |
Equivalent Sample Rate | 100 GS/s |
Memory | 500 kpts/Ch |
Acquisition Modes | |
Averaging | Selectable Number of Sweeps: 4, 16, 32, 64, 128, 256 |
Peak Detect | 1 ns |
Interpolation | Linear |
Enhanced Resolution | na |
Sequence Mode | na |
Acquisition Processing | |
Averaging | Selectable Number of Sweeps: 2, 4, 16, 32, 64, 128, 256 |
Peak Detect | 1 ns |
Enhanced Resolution (ERES) | na |
Interpolation | Linear |
Triggering System | |
Modes | Normal, Auto, Single, Stop |
Sources | Ch 1 - Ch 2, EXT, EXT/10, AC Line |
Coupling Mode | AC, DC, LF Rej, HF Rej, |
Hold-off by Time or Events | 200 ns - 50 s |
Internal Trigger Range | ±5 divisions from center |
Trigger Sensitivity | 0.5 division: DC - 10 MHz 2.0 divisions: 10 MHz - 200 MHz |
External Trigger Sensitivity | Ext: 50 mV from DC to 10 MHz 250 mV from 10 MHz to 200 MHz Ext/10: 0.5 V from DC to 10 MHz 2.5 mV from 10 MHz to 200 MHz |
External Trigger Input Range | Ext: ±0.5 V, EXT/10: ±5.0 V |
Display | |
Type | Color 7.5" TFT-LCD |
Resolution | VGA: 640 x 480 |
Grid Styles | YT, XY |
Trigger Types | |
Optional Advanced Triggers | na |
Optional Serial Data Triggers | na |
Internal Storage | |
Waveform Storage | 1 reference waveform |
Setup Storage | 5 setups |
Math | |
Number of Math Traces | 1 |
Standard Math Functions | Add, Subtract, Multiply, FFT |
Optional Math Functions | na |
Measurements | |
Number of Measurements Displayed | 4 |
Measurement Parameters | Base, Cyclical Mean, Cyclical RMS, Duty Cycle, Fall Time (90% - 10%), Fall Time (80% - 20%), Frequency Integral, Maximum, Mean, Minimum, Number of +Pulses, Number of -Pulses, +Overshoot, -Overshoot, Peak-Peak, +Pulse Width, -Pulse Width, Rise Time (20% - 80%), Rise Time (10% - 90%), RMS, Skew, Skew@level, Top, Top-BAse |
Probes | |
Probes | Qty. (2) ÷10 Passive Probes |
Scale Factors | Automatic: ÷1, ÷10, ÷100, ÷1000 Manual: ÷1, ÷10, ÷20, ÷100, ÷200, ÷1000, ÷2000 |
Calibration Output | 1 kHz square wave, 0.6 Vp-p (typical), output to probe hook |
Interface | |
GPIB Port (optional) | 1 (optional) |
USB (Device) | 1 |
Ethernet Port | 1 (optional) |
USB (Host) | 1 |
Serial Port | na |
Power Requirements | |
Voltage | 90 - 264 VAC, 47 HZ - 420 Hz |
Max. Power Consumption | 75 VA |
Environmental and Safety | |
Temperature (Operating) | 0 °C to 40 °C |
Temperature (Non-Operating) | -20 °C to 60 °C |
Humidity (Operating) | 80% RH, 40 °C |
Humidity (Non-Operating) | 80% RH, 40 °C |
Altitude (Operating) | 2000 m |
Altitude (Non-Operating) | 15000 m |
Physical Dimensions | |
Dimensions (HWD) | 190 mm x 285 mm x 102 mm (7.5" x 11.2" x 4") |
Weight | 3.2 kg (7 lbs) |
- Quality Engagement
- Easy change and return
- Delivery Avaliable
- Favorable payment