MATRIX MST-8103 Programmable Electrical Safety Tester (0.050kVAC - 5.000kVAC, 0.001mAAC - 20.00mAAC, 0.050kVDC - 6.00kVDC, 0.1μADC - 10.00mADC)
Manufacturer: MATRIX Model: MST-8103 - Contact
Function Description: AC/ DC/ IR
Withstand Voltage Test:
Lose Out Electricity Pressure
AC:
Voltage Range: 0.050kV - 5.000kV
Voltage Waveform: Sine wave
Distortion: <3%
Working Frequency: 50Hz, 60Hz optional
Frequency Accuracy: ±1%
Output Power: 100VA (20mA)
Voltage Regulation Rate: ±(1.0% +50V) (rated power)
DC:
Voltage Range: 0.050kV - 6.00kV
Signal Source Frequency: 600Hz
Output Power: 50VA (10mA)
Voltage Regulation Rate: ±(1.0% +100V) (rated power)
Voltage Resolution: 1V
Voltage Test Accuracy: ±2%
Voltage Generation Method: DDS signal source plus class AB power amplifier
Electricity Flow Measurement Test Fan Surround
AC:
Current Range: 0.001mA - 20.00mA
Short Circuit Current (Momentary): >40mA
Current Resolution: 0.001mA
Current Accuracy: ±(2% of reading + 2 words)
Actual Current: OFF - 0.001mA - 20mA
DC:
Current Range: 0.1μA - 10.00mA
Current Accuracy: ±(2% of reading + 2 digits)
Discharge Function: Automatic discharge after the test (DCW)
Insulation Resistance Test:
Output Voltage: 0.050V - 1.000kV
Voltage Resolution: 1V
Voltage Test Accuracy: ±2%
Maximum Output Current: 10mA
Maximum Output Power: 10VA (1000V/10mA)
Output Instantaneous Short-Circuit Current: >20mA
Load Regulation: ≤1% (rated power)
Ripple (1kV): ≤3% (1kV, no load)
Discharge Function: Automatic discharge after the test
Resistance Measurement Range: 0.1ΜΩ - 10GΩ
Resistance Measurement Accuracy:
Voltage < 500V: 0.2ΜΩ - 1GΩ Accuracy: ±[10% reading + 5 words], 1GΩ - 10GΩ Accuracy: ±[20% reading + 5 words]
Voltage > 500V: 0.2ΜΩ - 1GΩ Accuracy: ±[3% reading + 5 words], 1GΩ - 10GΩ Accuracy: ±[7% reading + 5 words]
Arc Detection:
Measuring Range: AC, DC: 1mA - 20mA (9 gears, fine-tuning)
Comparators:
Discrimination Method:
Window comparator mode at I at the ON: When I at < I_x < I_on, PASS; when I_x ≤ I or I_x ≥ I_on, FAIL (article items I_at < I_on)
I Down OFF: When I_x < I_up, PASS; when I_x ≥ I_up, FAIL; insulation resistance judgment method is the same as above
Capping Current I on: AC: 0.001mA - 20mA, DC: 0.1uA-10mA
Current Upper Limit Setting I under: AC: 0.001mA - 20mA, DC: 0.1uA-10mA
Resistance Upper Limit Setting: OFF - 0.2ΜΩ - 106Ω
Resistance Lower Limit Setting: 0.2ΜΩ - 106Ω
Parameter Setting:
Voltage Rise Time: 0.1s - 999.9s
Voltage Drop Time: 0s - 999.9s (only after withstand voltage PASS)
Voltage Waiting Time: 0.3s - 999.9s (only DC withstand voltage, and meet the rise time + test time > waiting time)
Test Time Setting: 0.3s - 999.9s (when TIMER ON)
Time Accuracy: ±(0.2% setting value ± 0.1s)
Protocol: SCPI, Modbus
Storege: 105 test files can be programmed, with 25 test steps per file
Interfaces: HANDLER, SIGNAL, RS232C, RS485 (optional)
Size (WxHxD): 215x143x405 mm (without terminal)
Weight: 12kg
- Quality Engagement
- Easy change and return
- Delivery Avaliable
- Favorable payment