Power: 12.5 kVA

Transformer: Isolation transfomer

Full Load Efficiency: > 93%

Input Connection: Standard Terminal blocks

Output Connection: Standard terminal blocks

VOLTAGE

Input Range [PH-PH]: 350 – 440 Vac

Output [PH-N]: 1 - 50Vac

Regulation System [PH-PN]: Adjustable within the output voltage range

Sensing Function: Yes driven in current. MCB104 board with current sensors.

Total Harmonic Distortion [THD]: < 0,5%

Static Line Regulation: < 1%

Static Load Regulation: < 1%

Dynamic stability of the output voltage upon load variation: < 0.2% with 100ms stabilization time in thermic curve

CURRENT

Output and Regulation: single range from 5A to 250A

FREQUENCY

Input Range: 47Hz - 63Hz

Output [switchable from control panel and remote]: 50Hz and 60Hz [± 0,01%]

Output [adjustable from control panel and remote]: from 10Hz to 200Hz [± 1%]

OTHERS

Noise level: 60dBA

Power Protections: OVP, UVP, OCP, OTP

CONTROL PANEL

Commands: LCD display 4 x 40 characters + command buttons

Voltage and current LCD Display accuracy: ± 2 DIGIT

Voltage LCD Display resolution: ± 0.5Vac

Current LCD Display resolution: ± 1A

Frequency value visualization: Yes

Output Current Value Visualization: Yes

COMMUNICATION INTERFACES

Analog: MCB owned I/O 12 poles equipped with 0-10Vdc

RS232: Yes

Ethernet: Yes

Communication Protocols: 0-10Vdc over analog I/O 12 poles & SCPI over RS232 and Ethernet

Reference Voltage of remote controls: Common ground with ground line

MECHANICAL

Dimensions (W x H x D): 550 x 1100 x 800 mm

Weight: 150kg

ENVIRONMENTAL

Cooling: Air Forced Circulation

Operating Temperature: from 0° to +40°C

Storage Temperature: from -40° to +85°C

REGULATORY

Safety: EN 61000-6-2 (2005) + AC (2005), EN 61000-6-4 (2007)+A1(2011), EN 61010-1 (2010) + A1/AC (2019)

EMC: 2014/35/UE (LVD), 2014/30/UE(EMC)