Metrel MI 3394 XS Standard set End-Of-Line Safety Testing In Production (100 V – 5100 V; 500 V – 6000 V)
HV AC Programmable: 100 V – 5100 V / 10 V steps / Output power 500 VA max
HV AC Limits: Short circuit current > 200 mA / High limit current 100 mA
HV DC Programmable: 500 V – 6000 V / 50 V steps / High limit current 10 mA
Discharging time: Threshold limits 34 V, 60 V, 120 V
Earth continuity test (2W, 4W): Test currents 200 mA, 4 A, 10 A, 25 A
Insulation resistance (Riso, Riso-S): Test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
Substitute leakage (Isub, Isub-S): Test voltage < 50 V a.c. (current recalculated to 110 V or 230 V)
Differential leakage: Measured @ mains voltage
Earth leakage (Ipe): Measured @ mains voltage
Touch leakage: Measured @ mains voltage
Leaks & Power: Measured @ mains voltage
Parameters: P, S, Q, PF, THDu, THDi, Cosø, I, U
Communication interfaces: RS232, USB, Ethernet, and Bluetooth
Memory: microSD card support up to 32 GB
Protection Classification: Perfectly suited for work places in accordance with EN 50191
Fuses: F1, F2 (F 3.15 A / 250 V)
Rack Integration: A 1584 19" Rack mount adapter supported
MI 3394 CE MultiTesterXS
A 1584 19” Rack mount adapter for MI 3394 CE MultiTesterXA/XS
A 1493 Mains cable EU13 / Schuko, 3 x 1.5 mm2, 2 m
A 1695 Grounding cable, 2 m
A 1495 P/L Adapter for connection of I/O signals
A 1727 Cable USB, type AB, 1 m