Mettler Toledo 58045001 Bioburden Analyzer 7000RMS Online

Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Use: Indoor use

Weight: 73.4 lbs (33.3 kg)

Voltage: MAINS supply voltage fluctuations up to ±10% of the nominal voltage of 100 - 240 VAC 50 - 60 Hz TEMPORARY OVERVOLTAGES occurring on the MAINS SUPPLY TRANSIENT OVERVOLTAGES: up to levels of OVERVOLTAGE CATEGORY II

Altitude: Up to 6562' (2000 m)

Flow Rate: 30 mL/min – 100 mL/min

Flow rate: 31 mL/min

Wall Mount: Anti-vibration shelf required (P/N 58 079 700)

Environment: Pollution degree 3

Analysis Time: Continuous

Response Time: 3 seconds (1 mL)

Inlet pressure: 21 - 80 psig (2 - 5.5 bar(g)) Calibration, cleaning and grab sample requires sample pressure of 0 psig (0 bar(g) Process pressure above 80 psig (5.5 bar(g)) requires optional High Pressure Regulator (P/N 58 091 552)

Type / Quality: Purified Water (PW), Ultrapure Water (UPW), Water for Injection (WFI)

Detection limit: 2 AFU (Auto Fluorescent Units)

Inlet connection: 0.125" (3 mm) O.D.

Measurement Range: 1 -10,000 AFU / mL

Outlet connection: 0.125" (3 mm) O.D.

Data communication: 5 - 20 mA standard, with configurable output ranges Analog output channels Ethernet - standard RJ 45 / Wi-Fi capable SCADA connectivity via Modbus TCP USB

Dimensions (HxWxD): 616 mm x 564 mm x 305 mm

Enclosure Material: Stainless Steel

Power Requirements: 100 - 240 VAC 50 - 60 Hz 5A Use the power cord included with the instrument 8.2' (2.5 m) cord length provided standard

Monitoring location: At-line to drain

Physical dimensions: (WxHxD) 22.2"(56.4 cm) W x 24.25"(61.6 cm) H x 12"(30.5 cm) D

Minimum detection size: ≥ 0.3 μm

Operating Range (Temp.): 0 °C – 37 °C

Environmental Temperature: 6 - 35 °C (41- 95 °F)

Humidity (non-condensing): 80% maximum relative humidity up to 31 °C (87.8 °F) decreasing linearly to 50% relative humidity at 40 °C (104 °F)

Operating Range (Humidity): 10 % – 90 %

Temperature (non-condensing): 6 - 90 °C (41-194 °F) Temperature below 15 °C or above 45 °C requires Sample Conditioning Coil (included)

Ambient temperature (non-condensing): 1 - 37 °C (32 - 98.6 °F) Temperature below 15 °C or above 45 °C requires Sample Conditioning Coil (included)