Micrometer size failed? How to edit instructions

08/23/2024 16:00:05

The micrometer is used to measure with quite high accuracy, but after a long period of use, there are many reasons why the measuring lines on the micrometer no longer match accurately. So how to effectively adjust the error of the micrometer? Follow EMIN in the article below!

Zero error of the micrometer and how to fix it

The cause of 0 error in mechanical measuring tools is often due to external factors such as falling, impact leading to warping, rust, or wear of the device after long-term use. In addition, zero error can also come from the user's incorrect calibration or not knowing how to calibrate correctly, inaccurate measurement operations, or due to parallax problems - a phenomenon that occurs when the viewing angle is not correct. causing misreading errors.

Error 0 can be due to many different reasons, not only due to external influences. Usually this error occurs in two cases:

1. If the zero line of the Vernier scale is below the main scale, this error is called positive zero error.

2. If the zero line of the Vernier scale is on the main scale, this error is called negative zero error.

Zero error directly affects the measurement result, so if the error is not too large, you can simply adjust the measurement result by adding (with negative zero error) or subtracting (with positive zero error). ) with ruler precision. However, when high precision is required, professional micrometer calibration is necessary.

How to fix the error of dividing lines on the micrometer that do not match

Thimble (secondary ruler), plays an important role in determining correct measurement results. When the micrometer encounters an error where the division lines do not match, you can adjust them so that the 0 lines on the main scale and sub-meter match.

First, turn the knob so that the two measuring heads of the micrometer touch each other. Use the locking screw to fix the micrometer to avoid movement during adjustment. Next, use a small wrench to tighten the main ruler. After doing this, check to see if the 0 lines on the main ruler and the secondary ruler coincide.

If the divisions still do not match, it may be due to a zero error. At this time, it is necessary to continue to recalibrate to ensure accurate measurement results according to the requirements of the job.

Related articles: Principles for choosing a micrometer for beginners

How to preserve and clean the micrometer to prolong its life

Proper cleaning and storage not only helps minimize errors when using a micrometer but also prolongs the life of the device, helping it to operate stably throughout the measurement process.

Clean the micrometer properly

To avoid errors such as zero or error, you need to clean the micrometer before and after use. Basic cleaning can only remove surface dust and dirt without completely eliminating factors that can cause errors.

Before use, check the anvil and spindle of the micrometer to ensure they are aligned and not dented. Gently clamp a clean sheet of paper between the surfaces, then pull the paper out to clean. Next, gently close the micrometer and check the thimble to see if the 0 lines on the main scale and sub-scale match.

After use, wipe the micrometer with a clean cloth moistened with a little oil to protect the surfaces from dirt and oxidation.

Store the micrometer properly

Periodically check and calibrate the micrometer to ensure no errors occur during the measurement process. Before and after use, wipe with a soft cloth to remove dirt from the micrometer surfaces. Apply a thin layer of oil after each use to prevent rust and help parts move smoothly.


After use, store the micrometer in a dry place, away from moisture. Do not stack instruments on top of each other to avoid damaging or affecting the function of the micrometer.

Related News

What is the required TDS level for shrimp ponds?
06/12/2026 14:26:27

What is the ideal TDS level for a shrimp tank? Many people spend a lot of time monitoring pH, temperature, and filtration systems but overlook TDS. Only when shrimp grow slowly, their colors fade, they have difficulty molting, or die off sporadically do they start checking their water source and discover that this indicator has long been out of the right range

Signs that the electrodes in your TDS meter are degraded and need replacing
06/12/2026 11:43:51

TDS meters can operate reliably for many years, but the electrodes are the most subject to wear and tear. Each time a measurement is taken, the sensor surface comes into direct contact with water, dissolved minerals, and various other chemical components. This continuous process means the electrode's responsiveness gradually decreases over time.

Can metal detectors locate underground pipes and cables?
06/10/2026 19:17:37

Metal detectors operate on the principle of passive electromagnetic induction and can only detect isolated metal objects such as gold, copper, and iron. These devices cannot trace utility paths because they cannot differentiate the direction or depth of long, buried continuous pipes. For insulated electrical cables or plastic pipes, metal detectors are completely ineffective as there is no AC current to generate a magnetic field. Furthermore, the detection depth of standard consumer metal detectors is typically limited to 1 - 2 meters for small objects, whereas underground utility lines are often buried 3 - 5 meters deep or even more.

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts