For full functionality of this site it is necessary to enable JavaScript.

NGI N6909-600-360 Single-Channel High Power DC Electronic Load (9kW, 600V, 360A)

Voltage: 600V

Current: 360A

Power: 900W

Min operating voltage: 4.5@36A/ 4.5V@360A

CC mode

Range: 0~36A/ 0~360A

Setting Resolution: 1mA/ 10mA

Setting Accuracy (23±5℃): 0.05%+0.05%F.S.

CV mode

Range: 0~60V/ 0~600V

Setting Resolution: 1mV/ 10mV

Setting Accuracy: (23±5℃) 0.05%+0.05%F.S.

CP mode

Range: 0~9000W

Setting Resolution: 0.1W

Setting Accuracy (23±5℃): 0.5%+0.5%F.S

CR mode

Range: 0.04Ω~166Ω / 0.7Ω~1666Ω

Setting Resolution: 16 bits

Setting Accuracy (23±5℃): 0.35%+18.8mS / 0.35%+1.88mS

Slew Rate

Current: 6~360A/ms / 360~18000A/ms

Voltage: 8~400V/ms 400~4000V/ms

Power: 6~360A/ms / 360~18000A/ms

Resistance: 6~360A/ms / 360~18000A/ms

Voltage Measurement

Range: 0~60V/ 0~600V

Readback Accuracy (23±5℃): 0.05%+0.05%F.S.

Current Measurement

Range: 0~36A / 0~360A

Readback Accuracy (23±5℃):0.05%+0.05%F.S.

Power Measurement

Range: 0~9000W

Readback Accuracy (23±5℃): 0.5%+0.5%F.S. 

Interface: LAN/RS232/CAN

AC Input: Single phase, 220V AC±10%, frequency 47Hz~63Hz

Sampling Frequency: 25Hz

Communication Response Time: ≤10ms

Operating Environment: Altitude: <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa

Temperature: Operating temperature: 0℃~40℃, storage temperature: -20℃~60℃

Net weight: Approx. 81kg

Dimension: 9U, 397.5(H)*482.0(W)with handle*612.0(D)mm

Details

Datasheet

  • Quality Engagement
  • Easy change and return
  • Delivery Avaliable
  • Favorable payment

Apply your mail to get promotion information