Applicable Gas: NO
Model: OC-F08 NO (0~2000ppm)
Detecting Range: 0~2000ppm
Sampling: Diffusion or
pump-suction, circulation selectable
Accuracy: ≤±3%F.S
Repeatability: ≤±1%
Zero drift: ≤±1%(F.S/year)
Sensor Type: Electrochemical
sensor
Sensor Life: 2~3 years
Response Time: (T90) ≤20s
Alarming mode: Audible-visual
alarm(Optional)
Operating Environment
Temperature: -30℃~60℃ (Customized for special
demands)
Humidity: ≤95%RH
(non-condensing); if >90%RH, can add the filter
Pressure: 86kPa~106kPa
Working Voltage: 24V DC(16~30VDC)
Output Signals
(Standard)Three-wire system
4~20mA standard signals output, available for PLC, DCS, etc;
(Optional) Four-wire system
RS485 digital signal output;
(Optional) Frequency signal
200~1000Hz output;
Two-level relay output: 220VAC
0.5A, 5VDC 0.5A
Installation Means: Wall
mounted, Pipe type(Thread:M40*1.5 )
Material of Body: Cast aluminum
Explosion-proof Index: Ex d IIC
T6
Protection Grade: IP66
Electrical Interface:
3/4″NPT(Female Screw)、1/2″NPT(Female
Screw)
Transmit Distance: ≤2000m
Dimension: 210 mm×140 mm×92 mm(L×W×H)
Weight: About 1.5Kg
Standards:
GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010