Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
CMRR: 100 dB
Loops: 0 to 99
Width: 53.3 mm
Height: 53.3 mm
Length: 8.21 mm
Weight: 226 g
Accuracy: ± 0.2 %
Contacts: Twin bifurcated
Input Type: Thermocouple, RTD, mA, Voltage
Form factor: 1/16 DIN
Display Size: 9.2 mm (.36 in)
Display Type: 4 Digit LED
Accuracy Note: ± 0.2% FS, ± 1 digit
Events/Alarms: 1 to 8
Memory Backup: Solid State
Output Detail: 4 to 20mA (500 ohm max.), Relay;Output #1: Reverse- or direct-acting, configured from menu Output #2: Reverse- or direct-acting, configured from menu Mechanical Relay: Rated 5 A @120 Vac, 3 A @ 240 Vac, normally open (NO), normally closed (NC) (output 1); rated 5 A @120 Vac, 3 A @ 240 Vac, NO (output 2) Current: 4 to 20 mA, 500 Ω maximum (suffix F1, F2); 4 to 20 mA, 1000 Ω maximum (suffix FH1, FH2) Voltage: 20 Vdc pulse Solid State Relay: SSR, 120/240 Vac, zero voltage switched, rated 1 A continuous, 10 A surge @ 25°C (77°F) Transducer Power Supply: 5, 10, 12, 15 Vdc ± 10% ;Alarm Output:Mechanical relay rated 5 A @ 120 Vac, 3 A @ 240 Vac, NO; optically isolated SSR rated 1 A, 120/240 Vac @ 25°C (77°C); DC alarms, 24 Vdc
Output Signal: Current
Ramp Setpoint: 1 to 9999 minutes
Ramp and Soak: 8 Ramp & Soak
Repeatability: ± 1 count
Sampling Rate: 10 Hz (10 updates/second)
Control Output: SPDT Relay, Analog Current
Data Interface: None
Ramp/Soak Time: 0 to 9999 minutes
Supply Voltage: 100 to 250 Vac
Input Type Note: Input Type: See input table on next page Digital Input: For remote setpoint, remote standby or ramp/soak run and hold Thermocouple Lead Resistance: 100 Ω maximum for rated accuracy Decimal Position: Selectable
Measuring Range: Type J (Iron-Constantan): -200 to 760°C, Type K (CHROMEGA®-ALOMEGA®): -270 to 1354°C, Type T (Copper-Constantan): -270 to 400°C, Type N (OMEGALLOY®) : -268 to 1300°C, Type R (Pt/13%Rh-Pt) : -50 to 1768°C, Type S (Pt/10%Rh-Pt) : -50 to 1768°C, Type B (Pt/30%Rh-Pt/6%Rh) : 0 to 1820°C, Type C (W/5%Re-W/26%Re) : 0 to 2315°C, Type E (CHROMEGA®-Constantan) : -150 to 1000°C, NNM 18% molybdenum vs nickel -06% cobalt : 0 to 1410°, Platinel II : -100 to 1232°C, RTD ((3-wire) 100 Ω Pt) : -200 to 850°C, RTD ((3-wire) 100 Ω Pt) : -199.9 to 375.0°C, 0 to 1V : Scalable (-1999 to 9999) selectable 1 to 5V : Scalable (-1999 to 9999) selectable 0 to 5V : Scalable (-1999 to 9999) selectable 0 to 10V : Scalable (-1999 to 9999) selectable 10 to 50 mV : Scalable (-1999 to 9999) selectable 0 to 50 mV : Scalable (-1999 to 9999) selectable 0 to 10 mV : Scalable (-1999 to 9999) selectable 0 to 100 mV : Scalable (-1999 to 9999) selectable 4 to 20 mA : Scalable (-1999 to 9999) selectable 0 to 20 mA : Scalable (-1999 to 9999) selectable
Remote Setpoint: N/A
Measurement Type: Current, Temperature, Voltage
Number of Inputs: 1
Cutout Dimensions: 45 x 45 mm
Display Type Note: Dual LED—4-digit, orange: process display; green: menu/parameter display; 9.2 mm (0.36")
Enclosure Ratings: IP65, NEMA Type 4X
Relative Humidity: 90% RH, non-condensing
Supply Power Note: 100 to 250V, 50/60 Hz (single-phase); 120 to 250 Vdc, 24 Vac/24 Vdc (optional)
Supply Power Type: AC
Depth Behind Panel: 100 mm
Setpoint Resolution: 1 count/0.1 count
Electrical Connection: Screw Terminal
Series Mode Rejection: >70 dB
Temperature Stability: 5 μV/°C Max
Control Characteristics: Set point Limits: Limited to configured range for thermocouple and RTD; limited to scaled range; Alarms: Adjustable for high/low; selectable process or deviation; Rate (Derivative): 0 to 2400 seconds; Reset (Integral): 0 to 9600 seconds; Cycle Time: 0.2 to 120 seconds; Proportional Band: 1 to span of sensor; Dead band: Negative span to positive span of sensor; Hysteresis: 1 to span of sensor; Autotune Damping: Adjustable (low, normal, or high); Ramp to Set point: 1 to 9999 minutes; Autotune: Operator-initiated from front panel; Manual Control: Operator-initiated from front panel
Number of Control Outputs: 2
Cold Junction Compensation: 0.05°C/°C ambient
Operating Temperature, Max: 55 °C
Operating Temperature, Min: 0 °C
Hardware and Software Requirements, Min: CN8-SW (Optional Software): Minimum Hardware and Software Requirements: IBM PC or 100% compatible, Windows 95/98/NT; RS485 interface or RS232 to RS485 converter; Software Compatibility: CN8200 Series controllers; Software Capability: Supports up to 254 CN8200 Series controllers