Width: 6.1 mm
Height: 113 mm
Length: 115 mm
Weight: 70 g
Accuracy: ± 0.05 %
Mounting: DIN Rail 35 mm Standard, EN 60715
Approvals: CE, UL, RoHS
Stability: Load Stability: ≤0.01% of span/100 Ω
Input Type: Isolated thermocouple
Wire Gauge: 26 to 12 AWG
EMC Standard: NAMUR NE 21
Installation: Pollution degree 2 and measurement/overvoltage category II
Output Value: Process
Accuracy Note: CJC Accuracy: ±0.15°C
Output Detail: Current Output Programmable Signal Ranges:0 to 20 and 4 to 20 mA Range Limits (NAMUR NE43 Out of Range): Below 3.8 mA or above 20.5 mA for 4 to 20 mA output; 0 mA or above 20.5 mA for 0 to 20 mA output Sensor Error Detection (Dip Switch Selectable for Enable or None):Below 3.5 mA or above 23 mA for4 to 20 mA output; 0 mA or above23 mA for 0 to 20 mA output Incorrect DIP-Switch Setting Identification: 0 mA Output Error Level: DIP switch selectable for upscale or downscale Voltage Output Programmable Signal Ranges:0 to 10V, 2 to 10V, 0 to 5V and 1 to 5V Range Limits (Out of Range):Range ±2.5% Incorrect DIP Switch Setting Identification: 0V
Output Signal: Current, Voltage
Response Time: < 30 ms
LED Indicators: Green LED indicates operational status of the unit and input sensor
Supply Voltage: 16.8 to 31.2 Vdc
Load Resistance: Voltage Output :>10 kΩ min,;Current Output: 21 mA/600 Ω /12.6V max
Input Range Note: Sensor and Cable Specifications:5 kΩ per wire;Cold Junction Compensation (CJC): Internal or external (selectable);CJC Accuracy via External CJC ;(Pt100 RTD Sensor): Better than ±0.15°C (DRSL-TC-ISO only);CJC via Internally Mounted Sensor:Better than ±2.5°C;Open Thermocouple Detection:Yes (DIP switch selectable upscaleor downscale)
Number of Inputs: 1
EMC Immunity Note: NAMUR NE 21, A Criterion, Burst: <±1% of span (span = selected input range)
Electrical Output: 4 to 20 mA
Enclosure Ratings: IP20
Power Consumption: 0.7 W, Internal - 0.65 W
Relative Humidity: 0 to 95% RH (non-condensing)
Supply Power Note: 16.8 to 31.2 Vdc via power rail or connectors
Supply Power Type: DC
Response Time Note: Response Time (0 to 90%, 100 to 10%): <30 ms/300 ms (selectable, provides either fast response or signal dampening as needed)
Voltage Output Range: 0 to 10 Vdc
Additional Features 1: Isolated
Screw Terminal Torque: 0.5 Nm
Temperature Coefficient: <±0.01% of span/°C
Storage Temperature, Max: 85 °C
Storage Temperature, Min: -40 °C
Operating Temperature, Max: 70 °C
Operating Temperature, Min: -25 °C
Calibration Temperature, Max: 28 °C
Calibration Temperature, Min: 20 °C
Temperature Measurement Range: J: 100 to 1200°C, K: 180 to 1372°C