- Measuring function:
DC voltage DC: Measuring range; Resolution; Accuracy
60 mV; 0.01 mV; ± (0.5% from + 5 Dgt)
600 mV; 0.1 mV; ± (0.5% from + 5 Dgt)
6V; 0.001 V; ± (0.5% from + 5 Dgt)
60V; 0.01V; ± (0.5% from + 5 Dgt)
600V; 0.1V; ± (0.8% from + 5 Dgt)
1000V; 1 V; ± (0.8% from + 5 Dgt)
AC voltage AC (TRMS): Measuring range; Resolution; Accuracy
60 mV; 0.01 mV; @ 50 ... 60 Hz:
600 mV; 0.1 mV; ± (1% from + 5 Dgt)
6V; 0.001V
60V; 0.01V; @ 61Hz ... 1KHz:
600V; 0.1V; ± (3% from + 5 Dgt)
1000V; 1V
AC + DC TRMS: Measuring range; Resolution; Accuracy
6V; 0.001V; @ 50Hz ... 1KHz:
60V; 0.01V; ± (3% from + 40 Dgt)
600V; 0.1V
1000V; 1V
DC DC: Measuring range; Resolution; Accuracy
600 μA; 0.1 μA; ± (1% from + 5 Dgt)
6000 μA; 1 μA; ± (1% from + 5 Dgt)
60-mA; 0.01-mA; ± (1% from + 5 Dgt)
600-mA; 0.1-mA; ± (1% from + 8 Dgt)
6 A; 0.001 A; ± (1.5% from + 8 Dgt)
10 A; 0.01A; ± (1.5% from + 8 Dgt)
AC AC (TRMS): Measuring range; Resolution; Accuracy
600 μA; 0.1 μA; ± (1.2% from + 5 Dgt)
6000 μA; 1 μA; ± (1.2% from + 5 Dgt)
60-mA; 0.01-mA; ± (1.2% from + 5 Dgt)
600-mA; 0.1-mA; ± (1.2% from + 5 Dgt)
6 A; 0.001 A; ± (1.5% from + 8 Dgt)
10 A; 0.01A; ± (1.5% from + 8 Dgt)
4 ... 20-mA %: -25 ... 125%; 0.01%; ± 50 digits
AC AC Over Rogowski coil: measuring range; resolution; accuracy
30 A; 0.01A; ± (1.2% vMw + 10 Dgt)
300 A; 0.1 A
3000 A; 10 A
Resistance: Measuring range; Resolution; Accuracy
600 Ω; 0.1 Ω; ± (1.2% vMw + 10 Dgt)
6 kΩ; 0.001 kΩ; ± (1.2% vMw + 5 Dgt)
60 kΩ; 0.01 kΩ; ± (1.2% vMw + 5 Dgt)
600 kΩ; 0.1 Ω; ± (1.2% vMw + 5 Dgt)
6 MΩ; 0.001 MΩ; ± (1.2% vMw + 5 Dgt)
60 MΩ; 0.01 MΩ; ± (2.5% vMw + 10 Dgt)
Frequency: Measuring range; Resolution; Accuracy
40 Hz ... 100 kHz; 0.01 Hz ... 0.001 kHz; ± 0.5% of Mw.
Duty cycle: Measuring range; Resolution; Accuracy
20 ... 80%; 0.1%; ± (1.2% from + 2 Dgt)
Capacity: Measuring range; Resolution; Accuracy
999.9 nF; 0.1 nF; ± (1.2% from + 8 Dgt)
9.999 nF; 0.001 μF; ± (1.5% from + 8 Dgt)
999.9 nF; 0.1 μF; ± (1.5% from + 8 Dgt)
99.99 n.f.; 0.01 mF; ± (2.5% vMw + 20 Dgt)
Temperature with Thermocouple type K: Measuring range; Resolution; Accuracy
-40 ... 600°C / -40 ... 1112°F; 0.1°C / 0.18°F; ± (1.5% from + 3°C / 5.4°F)
600 ... 1000°C / 1112 ... 1832°F; 1°C / 1.8°F; ± (1.5% from + 3°C / 5.4°F)
- General technical data:
Isolation: Class 2 Double insulation
Casing: IP67 plastic housing
Diode test: 1.5-mA test current; 3V DC open circuit voltage
Continuity test: Alarm tone if resistance < 50 Ω
Display: 6,000 digit OLED
Refresh rate display: 3 Hz
Automatic shutdown: After 30 minutes
Input impedance: 30 MΩ AC / DC V
AC response: TRMS
AC bandwidth: 50 ... 1000 Hz
Interface: Bluetooth BLE
Power supply: Digital multimeter: 9V block battery; Rogowski coil: 2 x 1.5V AAA battery
Fuses: 800-mA / 1000V fast acting (6.3 x 32 mm)
10 A / 1000V fast acting (10 x 38 mm)
Operating conditions: 0 ... 40°C / 32 ... 104°F, < 70% rh
Storage conditions: -10 ... 60°C / 14 ... 140°F, < 80% rh
Operating altitude: < 2000 m / 6561.7 ft above sea level.
Dimensions: 170 x 79 x 50 mm / 6.7 x 3.1 x 2 in
Weight: 342 g / < 1 lb
Security: UL61010-1 v3
CAT IV 600V
CAT III 1000V
Pollution degree: 2
Delivery scope:
1 x Voltmeter PCE-ODM 12
1 x Rogowski coil PCE-DM-CLAMP
1 x Set of test leads
1 x Thermocouple type K
1 x Thermocouple adapter
1 x Carrying bag
1 x 9V block batteries
2 x 1.5V AAA batteries
1 x User manual