PICO TA042 Differential Oscilloscope Probe (1400V, 100MHzx100/1000 CAT III)

Bandwidth: DC to 100 MHz (–3 dB) 

Attenuation: 100:1/1000:1

Rise Time: 3.5 ns

Accuracy: ±2%

Input impedance: 4 MΩ ∥ 7 pF each side to ground

Input voltage:

Max differential voltage input (100:1): ± 140 V (DC + peak AC) or 140 V RMS

Max differential voltage input (1000:1): ±1400 V (DC + peak AC) or 1000 V RMS

Common mode range: ±1400 V (DC + peak AC) or 1000 V RMS (100:1 and 1000:1) 

Absolute max. voltage (differential or common mode): ±1400 V (DC + peak AC) or 1000 V RMS CAT III (1/100 & 1/1000) 

Output voltage: 

Swing (into 50 kΩ load): ±1.4 V

Offset (typical): <±5 mV

Noise (typical): 0.9 mV RMS

Source impedance (typical): 50 Ω

CMRR (typical): 80 dB at 60 Hz; 50 dB at 1 MHz

Ambient operating temperature: –10 to 40 °C

Ambient storage Temperature: –30 to 70 °C

Power requirements:

Standard:4xAA cells or 6 V DC / 200 mA mains adaptor or regulated 9 V DC / 120 mA mains adaptor

Option: Power leads 

Length of input leads: 30 cm

Length of BNC lead: 90 cm

Weight: 500 g

Dimension (LxWxH): 207 mm x 83 mm x 38 mm