Manufacturer: PICO Model: TA042 - Contact
Bandwidth: DC to 100 MHz (–3 dB)
Attenuation: 100:1/1000:1
Rise Time: 3.5 ns
Accuracy: ±2%
Input impedance: 4 MΩ ∥ 7 pF each side to ground
Input voltage:
Max differential voltage input (100:1): ± 140 V (DC + peak AC) or 140 V RMS
Max differential voltage input (1000:1): ±1400 V (DC + peak AC) or 1000 V RMS
Common mode range: ±1400 V (DC + peak AC) or 1000 V RMS (100:1 and 1000:1)
Absolute max. voltage (differential or common mode): ±1400 V (DC + peak AC) or 1000 V RMS CAT III (1/100 & 1/1000)
Output voltage:
Swing (into 50 kΩ load): ±1.4 V
Offset (typical): <±5 mV
Noise (typical): 0.9 mV RMS
Source impedance (typical): 50 Ω
CMRR (typical): 80 dB at 60 Hz; 50 dB at 1 MHz
Ambient operating temperature: –10 to 40 °C
Ambient storage Temperature: –30 to 70 °C
Power requirements:
Standard:4xAA cells or 6 V DC / 200 mA mains adaptor or regulated 9 V DC / 120 mA mains adaptor
Option: Power leads
Length of input leads: 30 cm
Length of BNC lead: 90 cm
Weight: 500 g
Dimension (LxWxH): 207 mm x 83 mm x 38 mm
- Quality Engagement
- Easy change and return
- Delivery Avaliable
- Favorable payment