POLIMASTER PoliGate Vehicle G4 Radiation Portal Monitor
Manufacturer: POLIMASTER Model: PoliGate Vehicle G4 - Contact
Speed ( km/h):8
Control zone (W x H, m): 6x4.5
Minimal detectable amounts of nuclear and radioactive materials:
241Am, kBq, (µCi): 1500(41)
137Cs, kBq, (µCi): 160 (4.3)
60Co, kBq, (µCi): 100 (2.7)
57Co, kBq, (µCi): 200 (5.4)
133Ba, kBq, (µCi): 100 (2.7)
238U, g: 1300
235U, g: 80
239Pu,g: 2.3
239Pu, g (4 сm Pb)-
252Cf, neutron/s: -
Speed ( km/h):20
Control zone (W x H, m): 6x4.5
Minimal detectable amounts of nuclear and radioactive materials:
241Am, kBq, (µCi): 2300(62)
137Cs, kBq, (µCi): 240 (6.5)
60Co, kBq, (µCi): 150 (4.1)
57Co, kBq, (µCi): 300 (8.1)
133Ba, kBq, (µCi): 150 (4.1)
238U, g: 1900
235U, g: 120
239Pu,g: 3.4
239Pu, g (4 сm Pb)-
252Cf, neutron/s: -
Detectors : Gamma: plastic scintillators (PVT), 11 l Neutron: 10B/ZnS(Ag)
Energy range : 20 keV to 3 MeV
False alarm rate : < 1/1000 passages
Communication : Ethernet
Ingress protection : IP65
Weight (detection block): 120 kg (gamma detection block)130 kg (neutron detection block)
Dimension (detection block) : 1645×448×250 mm (H×L×W)
Power supply: 110 (90-132) V AC or 220 (180-264) V AC, 47-63 Hz;12 V built-in rechargeable battery (> 8 h of operation)
Standards compliance: IEC 62244:2019, ANSI N42.35-2016, IEC 61000-6-2:2016, IEC 61000-6-3:2011, IEC 61326-1:2012, ЕN 55022:2010 (class B), IEC 61010-1:2010, IEC 62244:2019,ANSI N42.35-2006 (partially)
Operating conditions:
ambient temperature: –30 °C to 50 °C
atmospheric pressure: 84 kPa to 106.7 kPa
relative humidity: up to 98 % at 40 °C
- Quality Engagement
- Easy change and return
- Delivery Avaliable
- Favorable payment