Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Sensors: Galvanic cell
Measuring Ranges: 0-25% Vol.
Lower Detectable Limit (LDL):0.1% Vol.
Max Current Draw (24VDC): 20 mA max, 2 wires
Response Time (T-90): 20 Seconds
Life Expectancy: 2-3 years with normal service
Accuracy(
Location: Indoor or outdoor. Explosion proof for Class I, Div. 1, Groups B, C, and D.
Temperature: -4°F to 113°F -20°C to 45°C
Humidity: 0 – 99% RH, non condensing
Housing
Housing J
Sensor: Stainless steel explosion proof
Controls
Zero: Sets transmitter output to 4 mA with zero output from sensor
Span: Sets transmitter output to proper level when span gas is applied
Output: 4 – 20 mA signal
Operating Voltage: 19-30VDC (250 OHMS impedance max)
Approvals: CSA NRTL
Controllers: Compatible with the following controllers: Beacon 110, Beacon 200, Beacon 410, and 800, also PLC and DCS systems