SSensor: analog Hall sensors
Nominal width: DN 32 / 40 / 50
Process connection: female thread G 1 1/4..G 2(further process connections available on request)
Metering range: 10..160 l/min For details see table "Ranges"
Pressure loss: ~ 4..7 bar at Qmax
Qmax.: up to 160 l/min
Tolerance: ±10 % of full scale value at constant viscosity
Viscosity stability: mean deviation ±7 %, max. 18 % (30-330 mm²/s) of full scale value
Pressure resistance: PS 200 bar
Medium temperature: -20..+85 °C, optionally -20..+120 °C
Ambient temperature: -20..+70 °C
Media oil: Wiring see section "Wiring"
Materials medium-contact
Brass construction:
CW614N nickelled, CW614N, 1.4305, 1.4310, hard ferrite
Stainless steel construction: 1.4571, 1.4310, hard ferrite
Supply: voltage 18..30 V DC
Power consumption: < 1 W
Outputs:
Current output 4..20 mA (alternatively 0..20 mA)
Max. load 500 Ohm
Ingress protection: IP 67
Electrical connection for round plug connector M12x1, 4-pole
Weight: see table "Dimensions and weights"
Conformity: CE
Installation location
Standard: horizontal inwards flow; other installation positions are possible; the installation position affects the metering and switching range.