Shaking motion: Orbital shaking
Temperature range: +4℃ to +70℃
Temp. control accuracy (*1): ±0.3℃ to ±1.0℃
Speed range (*2): 25 to 250 r/min
Shaking width: 70 mm
Platform size/Capacity: 700 × 500 mm (70RT: 680 × 480 mm) (Max. inside height: 420mm), Erlenmeyer flask 500 mL × 24, 5 L × 4
Door type: Clamshell split door (Divided into Upper and Lower, Upward opening and Front opening)
Maximum load: approx. 10 kg (Platform not included)
Ambient temp. range (*1): +5℃ to +30℃
Heating/Cooling method: Heater 700 W/Compressor 125 W
Program functions: 1 program, 9 segments (4 combinations can be saved): Temp., Shaking speed, and Time/per segment (Setting range: 00 h 00 min to 99 h 59 min),Temp. gradient function (*3)
Safety devices/functions: Leakage/Overcurrent breaker, Compressor overheating cut-off circuit, Alarm of abnormal sample temp. (Set as desired), Overload/Overvoltage protection, Fuse, Current limiter, Detecting the door opening and closing, Self-diagnosis function for temperature sensor error, Nonvolatile memory error, Breaking device when motor runaway
Dimensions (W × D × H)/Weight: 1110 (*4) × 716 × 930 mm, Approx. 190 kg
Power supply: AC100V/AC220-240V/12A built-in down transformer
Standard accessories: Universal shaking platform MT-7050 ×1 pc (LF)/ MT-6848 ×1 pc (LF-70RT) (*5), Drip tray ×1pc (LF)/Drain-reception plastic bottle with hose (LF-70RT), Vibration absorbing pad × 4 pcs, Spacer× 4 pcs (LF-70RT)
(*1)The temp. of the defrost function is not included. Also, the specifications may not be met outside of the ambient temperature range.
(*2)There is the limitation depending on the volume of vessels and the shaking diameter. See page 040.
(*3)The transfer time of temperature can be set up (within their capabilities).
(*4)Approx. 1550 mm when a delivery cart (not included) is installed.
(*5)Clamps are not included.
•Temp. range and Temp. stability may not be able to meet the specs when it is frozen by continuous operation. Required to defrost it regularly. •Due to the large size and weight of this product, transportation and installation costs will be charged separately.