Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Oxygen (O₂)
Detection principle: Galvanic isolation type
Measuring range: 0.0–25.0 VOL%
Detection range (service range): 25.1–50.0%
Indication accuracy: Within ±0.7 VOL% (JIS T 8201 compliant)
Display unit: 0.1%
Alarm setpoint:
First alarm: 18.1–20.8%
Second alarm: 18.0%
Combustible Gas (CH₄)
Detection principle: Catalytic combustion type
Measuring range: 0–100% LEL
Detection range (service range): None
Indication accuracy: Within ±5% LEL
Display unit: 1% LEL
Alarm setpoint:
First alarm: 1–29% LEL
Second alarm: 30% LEL
Carbon Monoxide (CO)
Detection principle: Fixed-potential electrolysis type
Measuring range: 0–150 ppm
Detection range (service range): 151–300 ppm
Indication accuracy: Within ±10 ppm
Display unit: 1 ppm
Alarm setpoint:
First alarm: 1–49 ppm
Second alarm: 50 ppm
Hydrogen Sulfide (H₂S)
Detection principle: Fixed-potential electrolysis type
Measuring range: 0.0–30.0 ppm
Detection range (service range): 30.1–150 ppm
Indication accuracy: Within ±1.5 ppm (JIS T 8205 compliant)
Display unit: 0.1 ppm
Alarm setpoint:
First alarm: 1–9.9 ppm
Second alarm: 10.0 ppm
Power:
AA alkaline batteries (2 pcs)
AC 100±15V (50/60Hz)
*Rechargeable AA NiMH batteries (2 pcs) can also be used
Battery Life: Approx. 15 hours continuously (alkaline battery / 20°C without lighting)
Size: 357 × 197 × 210 mm
Mass: Approx. 5.1 kg (including batteries)
Optional Products: Data management software, gas inlet pipe (20 m, 30 m)