Main ports: 1-1/2” #24 SAE Code 61 4-bolt flange
Top ports: 7/16” -20UN #4 SAE ORB
Flow Range: 5-160 US gpm
Maximum pressure: 3000 psi
Functional specification
Ambient temperature: 5 to 40 °C (41 - 104 °F)
Fluid type: Oils, fuels, water glycol, water oil emulsions
Fluid temperature: 5 to 90 °C (41 - 194 °F) continuous use.
Accuracy:
15 to 100% of range - 1% of indicated reading
Below 15% fixed accuracy of 1% of 15% of full scale
To obtain 1% of indicated readings a DHCR must be used. Accuracy with other readouts 1% of full scale.
Output:
Frequency - 20 -2000 Hz
Impedance - 3700 Ohm,
Inductance - 1kHz: 1.55H
Construction material
Flow body: High tensile Aluminium 2014A T6
Internal parts: Aluminium, Steel, Stainless Steel.
Transducer body: Aluminium, Steel - electroless nickel plated, Stainless Steel.
Seals: Viton seals as standard EPDM are available - please consult sales office