Control Unit Specifications:
Power: AC 220V ±10%, 50Hz
Capacity: 10kVA
Rated output: AC 250V
Rated output current: 40A
HV voltmeter range: AC 0-100kV DC 0-140kV; Accuracy: 1.0% of the reading±1digit (F.S)
LV ammeter range: 0-50A; Accuracy: 1.0% of the reading±1 digit (F.S)
Timing range: 0-9999S
Metering: Digital display
Weight: About 45kg
Dimension: 350mm(L)*300mm(W)*570mm
HV unit (DryType Testing transformer) specifications:
LV side voltage: 0-200V
LV side current: AC 0-50A
HV side voltage: AC 0-100kV/DC0-140kV
HV side current: AC 100mA
Capacity: 10kVA
Rating: 100% Rated 1minute, 50% continuous
Measuring voltage: AC 0-100V
No-load current: less than 3.5%
Impedance voltage: less than 8%
Weight: About 96kg
Dimension: 390mm(L)*390mm(W)*1100mm(H)
General Information:
EPTC-M Series AC DC Hipot Tester is suitable for hipot dielectric withstand test on various power electric products, units, insulating material and etc.
Features:
-Manual controlling.
-LED Display. Real time monitoring High voltage (HV) voltage, Low voltage (LV) current.
-High anti interference ability.
-Full protection functions: over-current, zero-starting sound light alarm, power switch protection.
-New type over-current relay, more accurate and reliable, to ensure the safety of the people and device.
-The control tester: Box type.
-AC/DC is selectable.
-Under castor, easy to move.