Operation using the display glass is the simplest

09/26/2024 09:55:10

How to use a stereo microscope can be of great help in the field of research and the laboratory. However, not everyone knows how to use a microscope properly. From adjusting the lighting to choosing the right magnification, this article will help you master the basic steps to most effectively observe samples with a microscope.

Concept of stereo microscope

Before getting into the main content of the article, we first need to understand about stereo microscopes.

Stereo microscopes belong to the optical microscope line, often used to observe samples with magnifications from 7X to 50X, and can be up to 100X when needed.

With this magnification range, stereo microscopes are widely used in many different fields, from education, biological research, to product inspection, error analysis, circuit assembly, and even is quality inspection.

So how to use a microscope properly and achieve optimal observation results? In the next section, EMIN will share the necessary steps when using a stereo microscope, helping you operate more easily and accurately with this device.

Steps to use a stereo microscope

Below are EMIN's instructions on how to use a stereo microscope:

Step 1: Place the microscope on a stable and easy-to-operate surface.

Step 2: Connect the glasses to the power source and turn on the light to start using.

Step 3: Turn the magnification adjustment knob to the lowest level, then bring the specimen into focus. Adjust the distance between the eyes to observe comfortably and without fatigue.

Step 4: Choose an objective lens suitable for the specimen and observation purpose.

Step 5: Adjust the lighting and condenser to optimize the light angle for the observed image. Adjust the diaphragm size depending on the objective selected.

Step 6: Look through the eyepiece, lower the objective lens close to the specimen, and adjust the level screw until the microscopic image appears.

Step 7: Use micro screws to fine-tune the observed image more clearly.

Step 8: After observing, take out the specimen, turn off the light, clean and store the microscope properly. 

Secrets to using stereo microscopes with objectives of all sizes

The secret to effectively observing samples with a stereo microscope is to choose just enough magnification to clearly see the details to be observed, ensure good depth of focus and wide optical field. You should only increase magnification when the light is bright. Brightness or resolution does not meet requirements.

In step 4 in the process of using a microscope, choosing the right objective lens for your observation needs is very important. To help you easily choose and operate, below is how to use a stereo microscope with different sized objective lenses that you can refer to.

Related articles: ZEISS microscope - The pinnacle of optical technology

Working with 10X objective lens

When combining the 10x objective lens with the 10x eyepiece, the sample can be magnified 100 times. This objective lens is often used to observe parasites, preliminary assessment of blood and marrow specimens,...

Steps to use a microscope with a 10X objective: First, place the specimen on the stage, rotate to select the 10x objective, and adjust the appropriate lighting to achieve clear viewing images at 10x magnification.

Working with 40X objective lens

To take a microfield with a 40x objective lens, it can be done directly with the 40x objective lens or through the 10x objective lens. How to do it as follows: First, take the microfield with a 10x objective lens as previously instructed. Once the field has been taken, increase the illumination and rotate to the 40x objective. Finally, use a micro-level screw to adjust the image to the clearest.

Working with 100X objective lens

To take a microfield with a 100x objective, you can do it indirectly through the 10x objective or directly with the 100x objective. First, adjust the light to the maximum level, then rotate to select the 100x objective lens. When observing, you need to use a large screw to raise the glass table until it almost touches the top of the glass base, then gently lift it a little more so that the objective lens is slightly pushed back inside. 

Note, do not over-twist to avoid breaking the specimen during operation.

Zeiss microscope brand - Stemi 508

And the model today EMIN wants to introduce is the Stemi 508 Stereo Microscope - a famous brand in Germany for microscopes.

Advantages of Stemi 508:

- Integrated camera connection port, helps observe and record easily.

- Magnification from 6.3x to 50x, can be upgraded up to 250x.

- Working distance is 92 mm, ensuring comfortable space when working.

- The distance between the two pupils can be flexibly adjusted from 55 mm to 75 mm, suitable for many users.

- 35° viewing angle, helping to bring a more natural and comfortable viewing experience.

Conclude:

Above are detailed instructions on how to use a stereo microscope. You should follow the correct steps to achieve the highest efficiency during use. If you have any questions regarding the use of stereo microscopes or other types of microscopes, please contact EMIN to receive advice and support from us.

See more at ZEISS MICROSCOPE

Related News

Which Vacuum Pump Should You Choose for a Microbiology Lab to Avoid Affecting Samples?
07/15/2026 14:45:07

Vacuum pumps are utilized in a wide range of microbiology laboratory procedures, from membrane filtration and the aspiration of supernatants following centrifugation to sample concentration and the support of negative-pressure systems. Selecting the appropriate pump not only ensures more stable operational processes but also minimizes the risk of sample contamination, reduces maintenance costs, and extends the equipment's lifespan

QCVN 25:2025/BKHCN Takes Effect: Do Businesses Need to Prepare Electrical Safety Testing Equipment?
07/15/2026 09:15:04

Electrical safety is consistently one of the primary criteria evaluated before electrical or electronic equipment—or industrial components—are released to the market. A product may operate reliably yet still fail to meet requirements if its insulation lacks sufficient durability, its grounding resistance exceeds permissible limits, or leakage current occurs during operation.

Why Is Associated Research Considered an Icon of Hipot Technology?
07/14/2026 09:05:30

When it comes to electrical safety testing equipment specifically Hipot testers—many QA/QC and testing engineers are familiar with the globally renowned brand Associated Research. A subsidiary of the parent company IKONIX, Associated Research (ARI) invented the world's first commercial Hipot tester.

What Is the Standard 3-Phase Voltage? How to Read Cabinet-Mounted Meters Without Errors
07/13/2026 15:09:18

Voltmeters are almost invariably found on the panels of electrical cabinets in factories, power stations, or generator systems. A glance lasting just a few seconds allows an operator to determine whether the power supply is stable or showing signs of abnormality. However, not everyone understands the significance of the displayed readings, particularly regarding three-phase electrical systems.

Distinguishing between ARI’s Hypot, HypotUltra, and HypotMax: Which device is right for your factory?
07/13/2026 09:48:30

Few people realize that the concept of the "Hipot Test"—or electrical safety testing—has long existed within the electrical equipment manufacturing industry. Driven by the growing need to verify the voltage withstand capabilities of conductors, motors, and electrical devices, the industry required a robust and virtually fail-safe method to detect insulation weaknesses before products reached the market.

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts