Input: 3-phase 4-wires,AC: 380V±57V,50/60Hz±3Hz
Output Capacity: 60kVA
Frequency Stability: 45.0~65.0H, 100H, 120H, 200H, 240Hz
Output Voltage: Single Phase,1.0~300.0V
Output Current: 272.7A
Line Regulation: ≤1%
Load Regulation: ≤1%
Modulating voltage range: ≤3V
Protection Mode: IGBT hot、IGBT OverCurrent、Transformer hot、Input Lack Voltage、Input Over Voltage、Output Lack Voltage、Output Over Voltage、Output Over Current、Output Over Power
Voltage Drop Compensation: 0.000~0.500Ω
Communication:RS232(Standard), RS485(Options), GPIB(Options), Ethernet(Options)
Remote Control:Analog Control(Options)
Dimension W×H×D(mm): 700*1330*1218
Weight(kg): 500
Product Detail
Main featrues
* Adopt FPGA digital technology,realize precision control and high quality sine wave output;
* Three-phase loading separately,start single phase output by U/V/W fast settings;
* Operating in over current shock(up to 3times of rated current)within2s, start the impact load of 1/3 capcity of power supply directly;
* Adjustable voltage and frequency during output status;
* Measurement:voltage,current,frequency,active power;
* Online monitoring:monitor IGBT temperature,transformer temperature, fan speed,imput voltage and other parameters during output status;
* Operating data recorders:keep the record of power supply status and alarm code automatically during alarming;
* Volage range:1.0-1.50.0V or 150.1-300.0V automatic adjustment,or locked at 1.0-300.0V;
* Shortcuts groups,power-off menory,shortcuts key and knobs operation;
* Fan speed will be adjustable automatically width the temperature of power supply to reduce the noise;
* Lock key,user-friendly design,automatically locking without operation for 5minutes to prevent from operation mistakes;
* Standard RS232,optional RS485,GPIB,Ethernet,analog control and other remote communication/control.
Order and Extensions
* ANFC Single phase AC power supply:1.0-300.0V/45.0-65HZ,100HZ,120HZ,240HZ,optional 15KVA,30KVA,45KVA,60KVA,90KVA,120KVA,180KVA,240KVA.Larger capacity can be modified.
* Communication interfaces:Standard RS-232,optional RS485,GPIB,Ethernet(Remarks:only can select one RS-232,RS-485,GPIB,Ethernet).
* Remote control interface:optional analog control interface.
* PC control software
Spec.
|
Model/Specification |
ANFC015S(F) |
ANFC020S(F) |
ANFC030S(F) |
ANFC045S(F) |
ANFC060S(F) |
ANFC090S(F) |
ANFC120S(F) |
|
|
Input |
3-phase 4-wires,AC: 380V±57V,50/60Hz±3Hz |
|||||||
|
Output Capacity |
15kVA |
20kVA |
30kVA |
45kVA |
60 kVA |
90 kVA |
120 kVA |
|
|
Output Frequency |
45.0~65.0Hz、100Hz、120Hz、200Hz、240Hz |
|||||||
|
Frequency Stability |
≤0.02% |
|||||||
|
Output Voltage |
Single Phase,1.0~300.0V |
|||||||
|
Output Current |
110V |
136.4A |
181.8A |
272.7A |
409.1A |
545.4A |
818.2A |
1090.9A |
|
220V |
68.2A |
90.9A |
136.3A |
204.5A |
272.7A |
409.1A |
545.4A |
|
|
Accuracy |
Voltage |
Resolution:0.1V Accuracy:0.2%×reading+0.2%×F.S. (45Hz—65Hz) |
||||||
|
Current |
Resolution:0.1A(<1000A)/1A(≥1000A) Accuracy:0.3%×reading+0.3%×F.S. |
|||||||
|
Frequency |
Resolution:0.1Hz Accuracy:0.05% |
|||||||
|
Power |
Resolution:0.1kW /0.01kW /0.001kW Accuracy: 0.45%×reading+0.45%×F.S. (45Hz—65Hz) |
|||||||
|
Line Regulation |
≤1% |
|||||||
|
Load Regulation |
≤1% |
|||||||
|
Voltage Distortion |
Linear load: THD<1.5%(110V±10%,220V±10%,45-65Hz); |
|||||||
|
Transient time |
20ms |
|||||||
|
Crest factor |
1.41±0.1 |
|||||||
|
Modulating voltage range |
≤3V |
|||||||
|
Over Power |
105%≤Output<110% the output will be stopped within 15 Sec. 110%≤Output<210% the output will be stopped within 5 Sec. 210%≤Output<310% the output will be stopped within 2 Sec. 310%≤Output<410% the output will be stopped within 1 Sec. 410%≤Output the output will be stopped immediately |
|||||||
|
Protection Mode |
IGBT hot、IGBT OverCurrent、Transformer hot、Input Lack Voltage、Input Over Voltage、Output Lack Voltage、Output Over Voltage、Output Over Current、Output Over Power |
|||||||
|
Voltage Drop Compensation |
0.000~0.500Ω |
|||||||
|
Softstart Time |
0.0~99.9S |
|||||||
|
Efficiency |
>86% |
|||||||
|
Shortcut Group |
7 groups |
|||||||
|
Online Voltage Adjustment |
The output voltage and frequency(45-65Hz) can be adjusted online under running status. |
|||||||
|
Communication/ Remote Control |
Communication:RS232(Standard)、</span |
|||||||