Input
Input range: 90 - 264 Vac (wide range) 127-300 Vdc
Frequency: 47 - 63 / 440 Hz (Safety rating 50/60 Hz)
Inrush current: < 50 A peak @ 230 Vac, cold start @ 25°C
Input power < 74 Watts
Efficiency: 87% average (as per Energy Star 2.0 standard) (NPS62-M, 80%)
EMI/RFI: FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted, VDE0878PT3 Class B conducted
Safety ground leakage current: 275 µA @ 50/60 Hz; 264 Vac input
Output
Maximum power: 60 W for convection
Adjustment range: ± 20% minimum
Hold-up time: 13/75 ms 115/230 Vac input line
Overload protection: Short circuit protection on all outputs. Case overload protected @ 110-160% of normal rating
Overvoltage protection 30-50% above nominal output
Remote sense: Compensated for 0.5 V lead drop max. Will operate without remote sense connected. Reverse connection protected.
Environmental Specifications
Operating temperature: 0° to 50°C ambient derate each output at 2.5% per degree from 50° to 80°C. -20°C start up
Storage temperature: -45°C to +85°C
Electromagnetic susceptibility: Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity: Operating; non-condensing 10% to 90% RH
Vibration: IEC68-2-6 to the levels of IEC721-3-2
MTBF demonstrated: > 550.000 hours at full load and 25°C ambient conditions
Ordering Information
Output Voltage: 12 V
Minimum Load: 0 A
Maximum Load with Convection Cooling: 5 A
Peak Load: 5.5 A
Regulation: ± 2%
Ripple P/P (PARD): 120 mV