Datacolor Spectro 700:Datacolor Spectro 700UV
Instrument Type:Horizontal Benchtop Spectrophotometer
Measurement Geometry:Diffuse illumination 8°viewing
Light Source:Pulsed xenon lamp
Sphere Diameter:152 mm/6in
Wavelength Range:360 nm -700 nm
Reporting interval:10 nm & 5 nm*
Photometric range:0-200%
Spectral Analyzer:Dual 256 diode array (software wavelength calibrated)
Wavelength Calibration Method:Via software adjustment
20 read repeatability on white tile using double flash (CIELAB) (1):0.03 (max)
Inter-instrument agreement: reflectance measurements (CIELAB)(1, 2 & 3):0.15 (avg) SCI; 0.30 (max) SCI
Sample Temperature:LAV aperture
IR Sensor Accuracy:±0.9°F/ ±0.5°C
Lens:4 position auto-zoom
Aperture Plates:
3 standard::
LAV (30 mm illuminated, 26mm measured):
SAV (9 mm illuminated, 5 mm measured):
USAV (6.6 mm illuminated, 2.5 mm measured):
2 optional::
MAV (20 mm Illuminated, 16 mm measured):
XUSAV (3.0 mm illuminated, 2.5 mm measured):
Aperture detection:Yes
Automated, adjustable UV calibration:Yes
UV cutoff filters:400 nm; 420 nm; 460 nm
Remote Measurement Button:Yes
Sample Positioning Camera:No
Transmittance:No
Inter-instrument agreement – regular transmittance at 550 nm:No
Inter-Instrument agreement -transmission haze measurements:No
Transmission sampling aperture size:No
Functional Operating Environment (2):Temperature: 5°C to 40°C, *Recommended Temperature: 23°C +/- 1°C, Max Relative Humidity 20%-85% non-condensing. Recommended Relative Humidity 50% +/- 15% non-condensing
Vertical Mount:Yes
Optional Accessories:MAV Aperture Plate, XUSAV Aperture Plate, Textile Skein Holder, Glass Aperture Plate LAV, Cuvette (10 mm), Compression Sample Holder, 10 mm Transmission Cell, TerryCloth Fixture Kit, White Backing Tile & Grey Backing Tile
Physical Specifications:
Color Display:3.5 inch RGB LCD
Display Resolution:320×240 pixel resolution
Power Requirements:Input Voltage: 100-240VAC +/- 10% Frequency: 50/60 Hz
Power Consumption:80VA
Weight:54.5 lbs (24.7 kg)
Dimensions:Height: 15.3″ (38.86 cm) Width: 12.3″ (31.24 cm) Front to back: Length: 16.4″ (41.66 cm) Sample Arm To Back: Length 18.3″ (46.48 cm)
Recommended option:User Color Performance Monitoring Tool: Guardian
Data Interface:USB: 2.0 / Ethernet