Determine COD index in wastewater, how to treat?

10/15/2025 14:03:15

Domestic wastewater is a source of many organic and inorganic pollutants, with notable indicators such as BOD, COD, Nitrogen or Ammonia. In which, COD is an important parameter reflecting the level of organic pollution in water and often exceeds the allowable threshold if not controlled. So how is COD measured and what measures are there to effectively handle it? Let's find out the details with EMIN in the article below!

What does the COD index in wastewater indicate?

COD (Chemical Oxygen Demand) or chemical oxygen demand is the amount of oxygen needed to oxidize all oxidizable organic and inorganic substances in a water sample.

When COD and BOD values ​​increase, the amount of dissolved oxygen (DO) in the water will decrease, directly affecting the life of aquatic organisms and causing imbalance in the ecosystem. Therefore, COD is a key indicator in assessing the level of pollution of water sources, from wastewater, surface water to domestic water. The higher the COD content, the higher the level of organic pollution, indicating that the water source contains many impurities that need to be treated promptly.

Hàm lượng COD trong nước thải sinh hoạt là bao nhiêu?

Normally, COD in domestic wastewater fluctuates between 200 - 500 mg/l, depending on the level of water use and the amount of organic matter generated. However, according to QCVN 40:2011/BTNMT (Column B), the allowable limit for discharge is only 150 mg/l. Thus, most domestic wastewater today has a COD index exceeding the standard from 0.3 to 2.3 times, needing to be treated before being discharged into the environment.

How to determine COD index in wastewater

To determine the COD index, people often use the oxidation method with potassium dichromate (K₂Cr₂O₇) in sulfuric acid (H₂SO₄) environment with silver catalyst. This process will oxidize organic compounds in the water sample, thereby determining the amount of oxygen needed for the reaction.

Laboratories or wastewater treatment plants often use specialized COD meters to shorten analysis time and increase accuracy. This device has the ability to automatically compare colors, giving quick results in just 15-20 minutes, instead of having to perform complicated manual titration steps.

Reasons why COD index exceeds standard in wastewater

COD exceeding the threshold is often caused by excessively high organic matter content, mainly due to domestic or production activities. Wastewater containing a lot of grease, detergents, leftover food, garbage or industrial waste all significantly increase the amount of oxygen needed for decomposition. 

In addition, wastewater treatment systems that are not regularly maintained are also common causes. Weak activated sludge, lack of oxygen or too high a load cause the organic matter decomposition process to be incomplete, leading to an output COD index higher than the allowable limit.

Common methods of COD treatment in wastewater today

Currently, there are many ways to treat COD depending on the level of pollution and the nature of wastewater.

- Biological method: using microorganisms to decompose easily biodegradable organic compounds, often applied to domestic wastewater and food wastewater.

- Physicochemical method: such as coagulation - flocculation, adsorption with activated carbon, or flotation. This method is effective for wastewater with a lot of suspended solids and grease.

- Chemical method: using strong oxidants such as ozone, H₂O₂, or chlorine to decompose organic compounds that are difficult to treat.

- Combining multiple technologies: in modern treatment systems, COD is controlled by combining biology and physico-chemistry, ensuring both efficiency and saving operating costs.

Device to support determination and control of COD index

In fact, determining the COD index is no longer as manual as before. Laboratories, water treatment areas or production facilities today often use specialized equipment to ensure the fastest and most consistent results. 

Some lines of Hanna Instruments COD measuring devices such as HI97106 or HI83314-02 are popular because of their ability to measure multiple parameters, integrating COD, pH and other water parameters in the same device. In addition, the sample preparation process is also simpler thanks to sample digestion machines such as Hanna HI839150-02, helping the oxidation reaction to take place evenly, reducing errors in measurement.

In addition, you can refer to more TOC/COD/BOD measuring devices in the TOC/COD/BOD Measuring Devices Category EMIN

Thanks to the application of these devices, monitoring and controlling COD in wastewater becomes convenient, accurate and better meets environmental requirements before discharge.

Related News

Which Vacuum Pump Should You Choose for a Microbiology Lab to Avoid Affecting Samples?
07/15/2026 14:45:07

Vacuum pumps are utilized in a wide range of microbiology laboratory procedures, from membrane filtration and the aspiration of supernatants following centrifugation to sample concentration and the support of negative-pressure systems. Selecting the appropriate pump not only ensures more stable operational processes but also minimizes the risk of sample contamination, reduces maintenance costs, and extends the equipment's lifespan

QCVN 25:2025/BKHCN Takes Effect: Do Businesses Need to Prepare Electrical Safety Testing Equipment?
07/15/2026 09:15:04

Electrical safety is consistently one of the primary criteria evaluated before electrical or electronic equipment—or industrial components—are released to the market. A product may operate reliably yet still fail to meet requirements if its insulation lacks sufficient durability, its grounding resistance exceeds permissible limits, or leakage current occurs during operation.

Why Is Associated Research Considered an Icon of Hipot Technology?
07/14/2026 09:05:30

When it comes to electrical safety testing equipment specifically Hipot testers—many QA/QC and testing engineers are familiar with the globally renowned brand Associated Research. A subsidiary of the parent company IKONIX, Associated Research (ARI) invented the world's first commercial Hipot tester.

What Is the Standard 3-Phase Voltage? How to Read Cabinet-Mounted Meters Without Errors
07/13/2026 15:09:18

Voltmeters are almost invariably found on the panels of electrical cabinets in factories, power stations, or generator systems. A glance lasting just a few seconds allows an operator to determine whether the power supply is stable or showing signs of abnormality. However, not everyone understands the significance of the displayed readings, particularly regarding three-phase electrical systems.

Distinguishing between ARI’s Hypot, HypotUltra, and HypotMax: Which device is right for your factory?
07/13/2026 09:48:30

Few people realize that the concept of the "Hipot Test"—or electrical safety testing—has long existed within the electrical equipment manufacturing industry. Driven by the growing need to verify the voltage withstand capabilities of conductors, motors, and electrical devices, the industry required a robust and virtually fail-safe method to detect insulation weaknesses before products reached the market.

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts