GFG G450 Multi-gas Detector
Manufacturer: GFG Model: G450 Origin: Germany - Contact
- Range:
+ LEL (0 … 100% LEL)
+ O2 (0 … 25% VOL)
+ H2S (0 … 100 ppm)
+ CO (0 … 300 ppm)
PHYSICAL FEATURES
Size 2.95 x 4.33 x 2.17 in.
Weight 10oz with O2, LEL, CO, H2S 14oz with above plus IR, CO2, or PID
Humidity 5% to 95% RH (non-condensing)
Temperature -4 to +131oF
EMI/RFI Complies with EMC Directive 89/336/EEC
IP Rating IP67
Number of buttons 3
Gases offered NH3, CO2, CO, Cl2, ClO2, LEL (Catalytic), LEL (Infrared), ETO, H2, HCl, HCN, HF, H2S, NO, NO2, O2, O3, COCL2, PH3, PID (VOC), SiH4, SO2
Maximum sensors used 6 (7 if used with motorized sample pump)
Battery types and run time (2) Two AA Alkaline batteries or Rechargable NiMH battery pack up to 25 hours
Wireless capable No
ALARMS
Adjustable alarm set points Yes - 3 user configurable alarm settings
Visual Bright 360owrap around LEDs, plus heterochromatic green/orange/red backlit display
Vibrating Yes
Audible 103dB or 95dB
IntelliFlash No
Certifications and approvals Class I, Div. 1, Gr. A,B,C,D, T3. Class I, Zone 0
CSA, IECEx, ATEX
Datalogging 55 hours @ 2 minute intervals - user configurable. Optional Micro SD card for expanded datalogging
Pump Available Yes - Attachable motorized sample pump operable in diffusion or sample draw mode while attached.
Pump Max draw 100ft+
Warranty Lifetime on instrument and electronics. Two year warranty on most sensors. Three years on LEL (catalytic and IR), O2, CO, H2S, IR (CO2) sensors. Optional 6 year sensor warranty available.
Bump/Calibration Test Station Yes
Technical Data | |||||||||||||||||||
Gases / warranty Combustible gases (CH4) Oxygen (O2) Carbon monoxide (CO) Hydrogen sulfide (H2S) COSH (dual channel CO and H2S sensor) |
Alarms
|
||||||||||||||||||
Detection range and resolution
|
Casing IP 67 (dust and highly water resistant) |
||||||||||||||||||
Accessories Datalogging kit Self powered detachable sample pump (run-time up to 25 hours) Spare battery cartridges (alkaline or rechargeable) Rechargeable (NiMh) battery cartridge with optional LED flashlight |
|||||||||||||||||||
Expected sensor lifetime
|
Weight 0.62 pounds (280 g) |
||||||||||||||||||
Dimensions 4.4x2.6x2 inches (66x11.8x50.8 mm) (HxWxD) |
|||||||||||||||||||
Rating and certifications (intrinsic safety) cCSAus Class I, Division 1, Group A, B, C, and D Hazardous locations Temp code T3 |
|||||||||||||||||||
Operational time Up to 25 hours |
|||||||||||||||||||
Charge time 4 hours with rechargeable NiMh cartridge |
|||||||||||||||||||
Power source 2 "AA" batteries or rechargeable NiMh battery cartridge |
|||||||||||||||||||
Temperature range -4° to +122°F (-20 to 50°C) ambient 5 to 95% r.h. (non-condensing) |