Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Sample Size: 15 composite sample sizes from 50ml to 2 liters plus a Full Bottle discrete setting (Approximate sizes at 4 foot head)
Operating Temperature: 32° to +158°F (0° to +70°C)
Materials:
Enclosure: Expanded UV protected PVC
Bottle: 2.5 gallon Polyethylene
Pickup Hose: 15 ft (4.6 m) reinforced PVC 1/4 inch ID polyethylene flexible tubing section with intake strainer
Pump Tubing: Norprene 1/4 inch ID, 7/16 inch OD
Sample Pump:
Flow Rate: 1000 ml per minute at a 4 foot head
Type: Peristaltic
Maximum Lift: ~20 feet (6 m)
Battery: Rechargeable 12V 5 AH Gel Cell
Battery Life: ~1 hour, continuous pumping under load
Standby: 3 months while still retaining enough power to run the pump to capacity
Flow Sampling System Open Channel Flow Monitor
Display/Keypad: 16 character x 2 line LCD backlit, 8-button tactile keypad
Capacity:
Flow: 7 digit maximum
Totalizer: 9 digit maximum
Level: 5 digit maximum
Display Resolution: 3 decimal places maximum, Auto-adjusting
Accuracy: Sensor accuracy + equation/table error + 0.1% + 1 digit
Units:
Level: Feet, inches, meters, centimeters
Volume: Cubic feet, gallons, million gallons, cubic meters, liters
Time: Seconds, minutes, hours, days
Flow: 20 Combinations of volume and time units above
Level Sensor Input: 4-20mA 2-Wire or 3-wire, 0-5VDC, 0-1VDC
Output: One 4-20mA scalable, 4 independent SPDT relays (8A @ 250VAC, 5A @ 30VDC resistive)
Power: 12VDC or 18-24VDC Input, +/-10%
Current Draw: 150mA Maximum, <13mA in Power Saving Mode
Flow Sampling System Datalogger
NOTE: FSS100 does not include datalogger
Memory: Non-volatile flash memory
Power: 12VDC rechargeable battery
Standby Current: 70uA Typical
Logging Current: 5mA Typical
Analog Sensor Inputs: 4-20mA
Resolution: 12-Bit, 4096 Steps
Sensor Warm-up Time: Programmable, 0-60 Sec
5 Input channels + flow rate + relay state + battery voltage monitor
Digital Inputs:
Maximum Input Voltage: 24VDC
Maximum Frequency: 100Hz
Minimum Pulse Width: 2mS
Maximum Count: 65,535 (16-Bit)
FSS300: 2
Sample Now Input: Sample-on-Demand input, software enabled
Maximum Input Voltage: 24VDC
Minimum Pulse Width: 2mS
Sample Modes:
Fixed Interval Programmable from 1 Sec. to >1 Year
High Speed 10 Samples per second
Logarithmic Sample Rate (Approximation)
Exception (Log only on deviation from previous reading)
Storage Capacity:40,879 Recordings for all inputs plus time
Data Overwrite: Select memory wrap or unwrap (unwrap will stop logging data once memory is full)
Communication Ports:RS-232 DB9 or USB Type B
Selectable Baud Rates: 9600, 19200, 28800, 38400, 57600, 115200
Clock: Synchronizes to the time and date of user's computer
Operating Temperature: Industrial, -40 to +185°F (-40 to +85°C) (Battery may not apply)
Enclosure: 22x17x9 inch (56x43x23 cm) (HxWxD)
Weight: 22lb (10 kg)

