An overview of the GT-KC52 for assessing rubbing-related colour damage and colour transfer, including its test modes, workflow, and selection considerations.

The GT-KC52 Circular Rubbing Colour Fastness Tester is designed to assess how coloured material surfaces respond to friction. It can be used when quality-control teams need to observe rubbing damage on a specimen and colour transfer to the rubbing pad. This type of evaluation is relevant to materials such as leather, plastics, and fabrics.

For manufacturers and laboratories, a repeatable rubbing procedure helps make visual comparisons more consistent across samples, production lots, or material options. The GT-KC52 applies circular rubbing under constant pressure with a wool felt rubbing medium. After the selected number of rubs is reached, the machine stops, allowing the operator to remove the sample and inspect the result.

GT-KC52 circular rubbing colour fastness tester

What the GT-KC52 Circular Rubbing Colour Fastness Tester Evaluates

Colour fastness to rubbing concerns the ability of a coloured surface to retain its appearance when exposed to friction. The evaluation can consider two visible outcomes: changes on the specimen surface and colour transferred from the specimen to the rubbing pad. Results may be assessed by reference to a standard gray scale where applicable to the laboratory’s procedure.

The GT-KC52 is described for circular rubbing tests performed with dry or wet wool felt. It also supports rubbing procedures involving perspiration, alcohol, and organic liquids. Any required test liquid must be prepared by the customer. Before adopting a particular procedure, the laboratory should confirm that its specimen preparation, rubbing medium, load, liquid, and assessment method match its own quality requirements.

Key Operating Features

Preset count and automatic stopping

The tester provides a counter for setting the intended number of rubbing cycles and displaying the actual count. Once the preset count is reached, the test stops automatically. This helps the operator run a defined test sequence rather than manually estimating the number of cycles.

Saved count during a manual stop

If a test is stopped manually before the preset count is reached, the current count can be retained so testing can continue later or be cleared to zero. The source information also notes that restarting the machine clears the current count, while the preset value remains the last setting used. Operators should therefore record important test details before powering down.

Load selection for the test requirement

Different rubbing evaluations may call for different loads. The GT-KC52 can be used with corresponding loads according to the test requirement. Confirm the required accessories and weights when specifying the equipment, as the supplied accessories may depend on the order.

Typical Dry Rubbing Test Workflow

A careful setup supports a more controlled result. First, position the tester on a level surface, verify the power connection, and check that the friction head lifts and lowers smoothly without jamming. Install the wool felt on the fixture, place the specimen with its test surface facing upward, lower the fixture, and install the required weights.

Next, select the counter mode and enter the required test count. The source procedure gives an example of 64 cycles and a speed setting of 150 ± 5 r/min. These values should be treated as a stated operating example, not as a universal setting for every material or test program. Clear the existing count before starting the test.

When the preset cycle count is reached, the unit stops. The operator can then lift the fixture, remove the specimen, and inspect the specimen and rubbing pad for surface change or transferred colour. Consistent documentation of the material, test condition, load, rubbing medium, cycle count, and observations makes later comparisons more useful.

Handling Heat-Sensitive Surface Coatings

Some specimens may have coatings with a low melting or softening temperature. In such cases, periodic stops may be necessary to reduce the risk of heat-related damage during rubbing. The source procedure describes placing a round aluminum block over the rubbed area and allowing the specimen to rest for 30 seconds before continuing. This is intended to help cool the test area during a dry rubbing procedure.

Because coating behaviour can differ significantly among materials, laboratories should define a controlled approach for interruptions and cooling when evaluating heat-sensitive surfaces. The key objective is to distinguish rubbing-related performance from unintended thermal effects.

What to Consider Before Selecting a Rubbing Colour Fastness Tester

Start with the materials your team needs to evaluate, such as leather, plastics, or fabrics. Then identify whether your process requires dry rubbing, wet rubbing, or tests using perspiration, alcohol, or other organic liquids. Review the intended rubbing count, applicable load, required rubbing pad, and the method used to judge surface change and colour transfer.

Also consider routine operation. A preset counter and automatic stop can support repeated testing, while the ability to resume after a manual stop may be useful when observing sensitive specimens. Finally, confirm the accessories required for the planned procedure, including weights and any blocks used for special test conditions.

Summary

The GT-KC52 Circular Rubbing Colour Fastness Tester provides a practical way to examine friction-related surface damage and colour transfer on coloured materials. Its circular rubbing action, selectable test conditions, count control, and automatic stopping function can support structured quality-control evaluations. A well-defined in-house procedure remains essential for obtaining meaningful and comparable observations.

Related News

Coating Adhesion Test Methods for Reliable Inspection
09/18/2026 10:10:46

A coating adhesion tester is an essential instrument for evaluating the quality of paints, varnishes, and protective coating systems. The coating must bond sufficiently well to the substrate or underlying coating layer to minimize peeling during use. Depending on the substrate material, coating system structure, test conditions, and evaluation objectives, operators can select from several adhesion test methods, including knife, tape, pull-off, and scratch tests.

Ultrasonic Coating Thickness Measurement on Wood
09/18/2026 10:06:58

A practical overview of ultrasonic coating thickness measurement for wood and wood products, including operating principles, measurement considerations, and process-control benefits.

Screen Printing Thickness Measurement Guide
09/18/2026 10:05:45

The PosiTector 6000 FS1 is a non-destructive coating thickness gauge that enables the monitoring of mesh, emulsion, stencil, and dried ink thicknesses in the screen printing process.

Reactive Power Compensation Capacitors Bulging or Exploding Before Their Design Lifespan
09/17/2026 16:10:45

The capacitor labels indicated a 10-year lifespan, yet after just two years of service, the casings began to bulge; some even exploded, accompanied by a popping sound and a burnt odor that permeated the electrical room. The maintenance team would install replacements, only for the exact same issue to recur a few months later. This cycle repeated multiple times before anyone finally questioned whether the failures were due to the capacitors reaching the end of their service life or because they were being subjected to conditions beyond their original design specifications.

Overheated Neutral Wire and Neutral Current Exceeding Phase Current: What Are the Causes?
09/17/2026 15:44:48

According to balanced three-phase circuit theory, the neutral current should ideally be zero or negligible compared to the phase current. Yet, technicians frequently discover during inspections at electrical panels that the neutral wire is extremely hot, with measured neutral currents sometimes even exceeding the current in individual phase wires. This is neither a rare occurrence nor a measurement instrument error; rather, it indicates that the system's loads are non-linear, generating harmonics that traditional conductor sizing methods fail to account for

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts