For full functionality of this site it is necessary to enable JavaScript.

INSIZE GCT-2400 Gas chromatography (ROHS2.0 O-Benzene fast sifter) (0-0.25Mpa (pressure), 0-1000ml/min (flow rate))

Specification

Analysis material: DI(2-ethylhexyl) phthalate (DEHP), Benzyl butyl phthalate (DBP), Dibutyl phthalate(BBP), Diisobutyl phthalate(DIBP)

Temperature control area: 8 signals

Temperature control range: Above room temperature 4-450°C, incremental 1°C, accurate: ±0.1°C

Program temperature rise step: 20th step

Program temperature rise rate: 0.1-60°C/min

Measurement range: 0-0.25Mpa (pressure), 0-1000ml/min (flow rate)

Injection valve: Automation

Sampler type: Capillary injection

Capillary column: Ø0.53mmx30mx0.50μm (shunt)

Detector: Hydrogen Flame lonization Detector (FID)

Detection limit: ≤3x10-12g/S (n-hexadecane)

Baseline noise: ≤1×10-14A (after 2 hours of instrument stabilization)

Baseline drift: ≤1×10-13A/30min (after 2 hours of instrument stabilization)

Linear range: ≥10°

Carrier gas: N2≥99.995%

Natural gas: H2≥99.995%

Combustion gas: Dry oil-free air

Data processing: Dedicated data workstation, can support multiple chromatographs of multiple channels of data processing at the same time (up to support 5000 chromatographs access), can automatically generate chromatograph folder, time folder, as well as according to the time, frequency or sequence of the named spectra file functions

Communication interface: Ethernet: IEEE802.3

Working environment: 5-35°C, 0-85%RH

Power: AC220V±10%, 50Hz (±0.5Hz), 3KW

Dimension (LxWxH): 600×560×500mm

Weight: 55kg


Standard Delivery: 

Main unit: 1 pc

Computer: 1 pc

Thermal cracker: 1 pc

Software: 1 pc

Standard sample: 1 set

Air generator: 1 set

Hydrogen generator: 1 set

Consumable and spare parts: 1 set*

*Including injection needles, injection pads, graphite pads, gas connection lines and other common consumables and tools

Details

■ The instrument adopts modularized structure design, easy and convenient maintenance, with no pre-treatment, no chemical reagents, no waste liquid and gas, no need for environmental assessment, convenient and quick, accurate screening and other advantages, general sample testing in 20 min

■ 7-inch color LCD touch screen, a new temperature control system, high precision temperature control, superior reliability and anti-interference performance, with the column box automatic back door system, near room temperature control ability has been improved, faster heating or cooling speed, each heating control unit has over-temperature protection function

■ With network remote control function, make the instrument in unattended, decentralized monitoring, centralized control become a reality. Adopting 100G or Gigabit Ethernet communication interface, built-in IP stack, the instrument can realize long-distance data transmission through the internal LAN and Internet, which is convenient to set up the laboratory, simplify the configuration of the laboratory, and facilitate the management of analytical data

Datasheet
  • Quality Engagement
  • Easy change and return
  • Delivery Avaliable
  • Favorable payment

Apply your mail to get promotion information