Output Voltage: 0~5kV(AC) 0~6kV(DC)± (2%+5V)
Upper Limit of AC Current: 0.01~20.00mA ± (2% + 2 digits)
Lower Limit of AC Current: 0.00 ~ 20.00mA ± (2% + 2 digits)
Upper limit of DC Current: 0.01~10.00mA ± (2% + 2 digits)
Lower limit of DC current: 0.00~10.00mA ± (2% + 2 digits)
Insulation resistance test voltage: 100~1000V ±(2%+5V)
Insulation Resistance:
Measuring Range (1-1000 MΩ):
Basic Accuracy: ± (2% of setting + 2 digits), Voltage ≥ 500V DC
Basic Accuracy: ± (5% of setting + 2 digits), Voltage ≥ 500V DC
Measuring Range (1000-5000 MΩ):
Basic Accuracy: ± (5% of setting + 2 digits), Voltage ≥ 500V DC
Basic Accuracy: ± (10% of setting + 2 digits), Voltage ≥ 500V DC
Measuring Range (5000-9999 MΩ): Reference value
LCD: 16 x 2 LCD
Test Time: 0.1 ~ 999.9s ± (2% + 0.05 sec) at 5V
Remote Control:
Input: Test, Reset
Output: Pass, Fail, Test-in-Process
Test Alarm: Buzzer, Light
Correction Methods: Software Calibration
Memory Device: Can remember the voltage, current, resistance, and time settings
Temperature/Humidity: 0°C ~ 40°C, ≤ 75% RH
Standard Attachment: 26002A
Manual
Characteristics:
Microcomputer digital design - production, operation is simple and safe to use
Maximum current: 20mA, AC - DC maximum current: 10mA
Voltage slow rise, in line with domestic and international safety standard requirements
Various test results - intuitive and accurate
Built PLC remote control interface
Keyboard lock and memory lock function
Automatic conversion between voltage and grounding insulation test modes
Adjustable time-voltage gradient for breakdown point detection
Lower limit resistance in current
Arc detection function (1-9 levels)
15 test memory models
RS232C interface and PLC interface available