Junray ZR-3260DA Intelligent Stack dust( gas) Tester (0~110L/min, 60~130kPa)
Manufacturer: Junray Model: ZR-3260DA - Contact
Dust technical parameter
Sampling flowrat: Range: (0~110)L/min, Resolution: 0.1L/min, Error: ±2.5%
Flowrate control: ±2.0%(voltage change ±20%,resistance range:3kpa—6kpa)
Dynamic pressure: Range: (0~2000)Pa, Resolution: 1Pa, Error: ±1.0%FS
Static pressure: Range: (-30~30)kPa, Resolution: 0.01kPa, Error: ±1.0%FS
Total pressure: Range: (-30~30)kPa, Resolution: 0.01kPa, Error: ±2.0%FS
Flowrate pre-meter pressure: Range: (-60~0)kPa, Resolution: 0.01kPa, Error: ±1.0%FS
Flowrate pre-meter temperature: Range: (-55~125)℃, Resolution: 0.1℃, Error: ±2.5℃
Velocity range: Range: (1~45)m/s, Resolution: 0.1m/s, Error: ±4.0%
Atmospheric pressure: Range: (60~130)kPa, Resolution: 0.1kPa, Error: ±0.5kPa
Auto tracking Precision: Range: -, Resolution: -, Error: ±3%
Max sampling volume: Range: 99999.9L, Resolution: 0.1L, Error: ±2.5%
Isokinetic trackingresponse time: ≤10s
Load capacity of pump: ≥50L/min(when resistance is 30 PA)
Size: (L275×W170×H265)mm
Weight: About 6.8kg(battery include)
Noise: <65dB(A)
Power consumption: <300W
Flue gas technical index
Sampling flow: Range: 1.0L/min, Resolution: 0.1L/min, Error: ±5%
O2(optional): Range: (0~30)%, Resolution: 0.1%, Error: Indication error:±5%Repeatability:≤1.5%Response time:≤90sStability:change within 1hExpected life:2 years in air (beside CO2)
SO2(optional): Range: (0~5700)mg/m3 Can extend to 14000mg/m³, Resolution: 1mg/m3, Error: Indication error:±5%Repeatability:≤1.5%Response time:≤90sStability:change within 1hExpected life:2 years in air (beside CO2)
NO(optional): Range: (0~1300)mg/m3 Can extend to 6700mg/m³, Resolution: 1mg/m3, Error: Indication error:±5%Repeatability:≤1.5%Response time:≤90sStability:change within 1hExpected life:2 years in air (beside CO2)
NO2(optional): Range: (0~200)mg/m3 Can extend to 2000mg/m³, Resolution: 1mg/m3, Error: Indication error:±5%Repeatability:≤1.5%Response time:≤90sStability:change within 1hExpected life:2 years in air (beside CO2)
CO(optional): Range: (0~5000)mg/m3 Can extend to 25000mg/m³, Resolution: 1mg/m3, Error: Indication error:±5%Repeatability:≤1.5%Response time:≤90sStability:change within 1hExpected life:2 years in air (beside CO2)
H2S(optional): Range: (0~300)mg/m3 Can extend to 1500mg/m³, Resolution: 1mg/m3, Error: Indication error:±5%Repeatability:≤1.5%Response time:≤90sStability:change within 1hExpected life:2 years in air (beside CO2)
CO2(optional): Range: (0~20)%, Resolution: 0.01%, Error: Indication error:±5%Repeatability:≤1.5%Response time:≤90sStability:change within 1hExpected life:2 years in air (beside CO2)
Product Detail
It adopts isokinetic sample and membrane filter (cartridge) weighing method to measure dust concentration while using electrochemistry or optical principle sensor to analyze O2, SO2, CO, NO, NO2, H2S, CO2. And also the velocity of flue gas, flue gas temperature, flue gas humidity, flue pressure and exhaust air rate etc.
Standards
EN13284-1
US EPA M5
US EPA M17
ISO 9096