KEYSIGHT AP5002A Microwave Analog Signal Generator (+ Option AP5002A-526, 9 kHz~26.0 GHz)

Frequency parameters / range

Frequency range: 9 kHz~26.0 GHz

Resolution: 0.001 Hz

Phase resolution: 0.1 deg

Settling time: 200 μs (Typical); 300 μs (Max)

Internal reference frequency: 100 MHz

Initial accuracy of internal reference: max ± 40 ppb (calibrated at 23 ± 3 °C at  the time of calibration, user adjustable)

Temperature stability (0 to 50 °C): max ±100 ppb

Aging 1st year: 0.5 ppm

Aging per day (after 30 days of operations): max 5 ppb

Warm-up time: 5min

Output of internal reference: 10 MHz~100 MHz (Both 10 MHz and 100 MHz reference output are available on the REF OUT port.)

Output power: 0 dBm

Output impedance: 50 Ω

Bypass internal reference input: 100 MHz, -5 to +10 dBm (High phase synchronous mode)

Phase lock to external reference; External input range: 1 MHz~250 MHz (User programmable)

Reference input level : min -5 dBm; typical: 0 dBm; max +13 dBm

Lock range: max ±1.5 ppm

Reference input impedance: 50 Ω