For full functionality of this site it is necessary to enable JavaScript.

Teledyne LeCroy WaveAce 101 Oscilloscope (40 MHz, 250 MS/s, 2 channels)


Vertical System

Bandwidth40 MHz
Rise time8.8 ns
Input Channels2
Bandwidth Limiters20 MHz
Input Impedance1 MΩ ± 2% || 17 pF ± 3 pF
Input CouplingAC, DC, GND
Maximum Input Voltage± 400 Vpk
Channel-Channel Isolation≥ 100:1 at 20 MHz
Vertical Resolution8 bits
Sensitivity2 mV/div - 5 V/div
DC Gain Accuracy±3%: 5 mV/div - 5 V/div (fixed gain ranges)
±4%: 2mV/div and variable gain ranges
Offset Range±2 V: 2mV/div - 100 mV/div
±40V: 102 mV/div - 5 V/div
 

Horizontal System

Time/Division Range10 ns/div - 50 s/div
Clock Accuracy100 ppm
Trigger and Interpolator Jitter2 ns (pk-pk)
 

Acquisition System

Single-Shot Sample Rate/Ch500 MS/s on 1 Ch
250 MS/s on 2 Ch
Equivalent Sample Rate25 GS/s
Memory4 kpts/ch
 

Acquisition Modes

AveragingSelectable Number of Sweeps:
4, 16, 32, 64, 128, 256
Peak Detect10 ns
InterpolationLinear, Sin x/x
Enhanced Resolutionna
Sequence Modena
 

Triggering System

ModesNormal, Auto, Single, Stop
SourcesCh 1 - Ch 2, EXT, EXT/5, AC Line
Coupling ModeAC, DC, LF Rej, HF Rej,
Pre-trigger Delaymemory/(2 * sample rate)
Post-trigger Delay260 Divisions
Hold-off by Time or Events100 ns - 1.5 s
Internal Trigger Range±6 divisions from center
Trigger Sensitivity1 division: DC - 10 MHz
1.5 divisions: 10 MHz - 40 MHz
External Trigger SensitivityExt: 200 mVpp from DC to 10 MHz
300 mVpp from 10 MHz to 40 MHz
Ext/5: 1Vpp from DC to 10 MHz
1.5 mVpp from 10 MHz to 40 MHz
External Trigger Input RangeExt: ±1.2 V, EXT/5: ±6 V
 

Display

TypeColor 5.7" TFT-LCD
ResolutionQVGA; 320 x 234 pixels
Grid StylesYT (12 horizontal divisions), XY
 

Trigger Types

Optional Advanced Triggersna
Optional Serial Data Triggersna
 

Internal Storage

Waveform Storage20 waveforms and 2 reference waveforms
Setup Storage20 setups
 

Math

Number of Math Traces1
Standard Math FunctionsAdd, Subtract, Multiply, Divide, FFT
Optional Math Functionsna
 

Measurements

Number of Measurements Displayed5
Measurement ParametersAmplitude, Average, Base, Burst Width, Cyclical RMS, +Duty Cycle, -Duty Cycle, Fall Time, Frequency, Max, Mean, Min, Overshoot, Peak-Peak, Period, Phase, Rise Time, RMS, Top, +Width, -Width, First Rising-Rising, First Rising-Falling, First Falling-Rising, First Falling-Falling, Last Rising-Rising, Last Rising-Falling, Last Falling-Rising, Last Falling-Falling
 

Probes

ProbesQty. (2) ÷10/1 Passive Probes
Scale FactorsManual: ÷1, ÷10, ÷100, ÷1000
Calibration Output1 kHz square wave, 3Vp-p (typical), output to probe hook
 

Interface

GPIB Port (optional)na
USB (Device)1
Ethernet Portna
USB (Host)1
Serial Port1
 

Power Requirements

Voltage100 - 240 VAC, 45 Hz to 440 Hz
Max. Power Consumption50 VA
 

Environmental and Safety

Temperature (Operating)10 °C to 40 °C
Temperature (Non-Operating)-20 °C to 60 °C
Humidity (Operating)85% RH, 40 °C
Humidity (Non-Operating)85% RH, 65 °C
Altitude (Operating)3000 m
Altitude (Non-Operating)15,266 m
 

Physical Dimensions

Dimensions (HWD)154 mm x 305 mm x 133 mm
(6" x 12" x 5.25")
Weight2.3 kg (5 lbs)
 

Warranty and Service

Warranty and Service3-year warranty; calibration recommended annually. Optional service programs include extended warranty and calibration services.

 

Details


  • Quality Engagement
  • Easy change and return
  • Delivery Avaliable
  • Favorable payment